P360E Zone 10 activation's mapped to scenario 1-4 default 1 Page 49
P361E Zone 11 activation's mapped to scenario 1-4 default 1 Page 49
P362E Zone 12 activation's mapped to scenario 1-4 default 1 Page 49
P363E Zone 13 activation's mapped to scenario 1-4 default 1 Page 49
P364E Zone 14 activation's mapped to scenario 1-4 default 1 Page 49
P365E Zone 15 activation's mapped to scenario 1-4 default 1 Page 49
P366E Zone 16 activation's mapped to scenario 1-4 default 1 Page 49
** Auto Answer Ring Count **
P369E Auto-answer ring count - default = 25 Page 54
** System reporting Options **
P370E System options (Default = 2,7) Page 46
1 = Enable communicator 5 = Reverse Style Pulse
2 = Fax defeat 6 = Spare
3 = Disable line monitoring 7 = Auto-Detect Modem Format
4 =DTMF or Pulse 8 = Force Bell103/V21
** Command Control Options **
P371E Command code for output control Page 42
P372E Command code for Area "A" control Page 42
P373E Command code for Area "B" control Page 42
P374E Command code for Area "C" control Page 42
P375E Command code to turn “MICROPHONE” On Page 42
** Contact ID Account Codes **
P376E Account number for Area "A" - default 0000 Page 51
P377E Account number for Area "B" Page 51
P378E Account number for Area "C" Page 51
Partition “B” Primary Output Options
P381E-P388E OPTIONS
P381E Area "B" primary options for output #1 - Default 1 1 = Standard zone activation's Page 24
P382E Area "B" primary options for output #2 - Default 1 & 2 2 = Stay Mode activation's Page 24
P383E Area "B" primary options for output #3 - Default 1 3 = Radio key chirps Page 24
P384E Area "B" primary options for output #4 - Default 1 4 = All zones sealed (Ready) Page 24
P385E Area "B" primary options for output #5 - Default 1 5 = 2 sec pulse arm/disarm Page 24
P386E Area "B" primary options for output #6 - Default 1 6 = Spare Page 24
P387E Area "B" primary options for output #7 - Default 1 7 = Day zone activation's Page 24
P388E Area "B" primary options for output #8 - Default 1 8 = Spare Page 24
** Dialler Reporting Options for partition “B” **
P389E Area B reporting options -Default = 1,2 Page 28
1 = Send set / unset 5 = Send set at the end of the exit delay (LED On)
2 = Send Stay Mode set/unset 6 = Send all zone restores at disarm only
3 = Send unset only after activation's 7 = Spare
4 = Send Stay Mode unset only after alarm 8 = Spare
Programming Partition “B” Parameters
P390E Time zones used for Area "B" auto arming/disarming - Default 0 Page 25
Partition “B” Specific Output Options
P391E-P398E OPTIONS
P391E Area "B" specific options for output #1 - Default 0 1 = Any bypass Page 24
P392E Area "B" specific options for output #2 - Default 0 2 = Auto-bypass warning Page 24
P393E Area "B" specific options for output #3 - Default 0 3 = Entry beeps Page 24