Page 66
Zone Response Time Settings
P420E Zone response settings default = 6 (value 1-31E) Page 31
** System Events to Scenario Mapping **
P421E Area A reports mapped to scenario 1-4 default 1 Page 50
P422E Area B reports mapped to scenario 1-4 default 1 Page 50
P423E Area C reports mapped to scenario 1-4 default 1 Page 50
P424E Keypad “Panic” (& buttons 1 & 3) mapped to scenario 1-4 default 1 Page 50
P425E Keypad “Fire” (buttons 4 & 6) mapped to scenario 1-4 default 1 Page 50
P426E Keypad “Medical” (buttons 7 & 9) mapped to scenario 1-4 default 1 Page 50
P427E Battery low mapped to scenario 1-4 default 0 Page 50
P428E Mains fail mapped to scenario 1-4 default 1 Page 50
P429E Phone line restore mapped to scenario 1-4 default 1 Page 50
P430E Radio PIR battery low mapped to scenario 1-4 default 1 Page 50
P431E Radiokey battery low mapped to scenario 1-4 default 1 Page 50
P432E Keypad tamper mapped to scenario 1-4 default 1 Page 50
P433E Cabinet tamper mapped to scenario 1-4 default 1 Page 50
P434E Radio panic mapped to scenario 1-4 default 1 Page 50
P435E Test calls mapped to scenario 1-4 default 1 Page 50
P436E Duress Alarm mapped to scenario 1-4 default 1 Page 50
P437E Supervised Radio Timeout mapped to scenario 1-4 default 1 Page 50
P438E Zone Inactivity Timeout mapped to scenario 1-4 default 1 Page 50
Low Zone Assignments (Zones 1-8)
P441E Zone is in Area "A" - Default all ) Page 31
P442E Zone is in Area "B" - Default none ) If zone is in both it is then a partition "C" zone Page 31
P443E Zone is a normally open/closed output - Default N/C 0ff = N/C On = N/O Page 31
P444E Zone is a radio detector - Default 0ff Page 31
P445E Stay mode zones - Default zones 1-4 Page 31
P446E Zone can be bypassed - Default all Page 31
P447E Auto-bypass zones - Default all Page 31
P448E Zone is a handover - Default none Page 31
P449E Two trigger zones -Default none Page 31
P450E Zone is 24Hr - Default none Page 31
P451E Zone is 24Hr Fire zone - Default none Page 32
P452E Zone is 24Hr Non-Latching zone - Default none Page 32
P453E Day zones - Default none Page 32
P454E Continuous day zone - Default none Page 32
P455E Siren lockout zones - Default none Page 32
P456E Access control door position input - Default none Page 32
P457E Access control request to exit input - Default none Page 32
** Multiple Zone Activation Reporting **
P458E Zones 1-8 will report multiple activation's - default on Page 32
Zones 1-8 Monitored for Inactivity
P459E Zones 1-8 will be monitored for inactivity - default none Page 32
Can Arm if Zone is Unsealed-Zones 1-8
P460E Can Arm if Zone Unsealed-Zones 1-8 - default none Page 32
High Zone Assignments (Zones 9-16)
P461E Zone is in Area "A" - Default all ) Page 32
P462E Zone is in Area "B" - Default none ) If zone is in both it is then a partition "C" zone Page 32
P463E Zone is a normally open/closed output - Default N/C 0ff = N/C On = N/O Page 32
P464E Zone is a radio detector - Default 0ff Page 33
P465E Stay mode zones - Default zones none Page 33
P466E Zone can be bypassed - Default all Page 33
P467E Auto-bypass zones - Default all Page 33
P468E Zone is a handover - Default none Page 33
P469E Two trigger zones -Default none Page 33