Page 73
P765E Voice message number mapped to zone 5 activation - default 1 Page 52
P766E Voice message number mapped to zone 6 activation - default 1 Page 52
P767E Voice message number mapped to zone 7 activation - default 1 Page 52
P768E Voice message number mapped to zone 8 activation - default 1 Page 52
P769E Voice message number mapped to zone 9 activation - default 1 Page 52
P770E Voice message number mapped to zone 10 activation - default 1 Page 52
P771E Voice message number mapped to zone 11 activation - default 1 Page 52
P772E Voice message number mapped to zone 12 activation - default 1 Page 52
P773E Voice message number mapped to zone 13 activation - default 1 Page 52
P774E Voice message number mapped to zone 14 activation - default 1 Page 52
P775E Voice message number mapped to zone 15 activation - default 1 Page 52
P776E Voice message number mapped to zone 16 activation - default 1 Page 52
**Arm/Disarm Command Control Status Message Addressing **
P777E Start of Status Message for Area “A” Command Control - Default 0 Page 43
P778E Start of Status Message for Area “B” Command Control - Default 0 Page 43
P779E Start of Status Message for Area “C” Command Control - Default 0 Page 43
**Output Command Control Status Message Addressing **
P781E Start of Status Message for Output #1 Command Control - Default 0 Page 43
P782E Start of Status Message for Output #2 Command Control - Default 0 Page 43
P783E Start of Status Message for Output #3 Command Control - Default 0 Page 43
P784E Start of Status Message for Output #4 Command Control - Default 0 Page 43
P785E Start of Status Message for Output #5 Command Control - Default 0 Page 43
P786E Start of Status Message for Output #6 Command Control - Default 0 Page 43
P787E Start of Status Message for Output #7 Command Control - Default 0 Page 43
P788E Start of Status Message for Output #8 Command Control - Default 0 Page 43
**Mains & Battery Voice Message Mapping **
P789E Voice message number mapped to Mains Failure - default 0 Page 52
P790E Voice message number mapped to Battery Low - default 0 Page 52
Defining Time Zones
P791E Time Zone 1 day of the week Default 0 TIME ZONE PROGRAMMING Page 40
P792E Time Zone 1 start time - Default 0 DAYS 1 - 7 Page 40
P793E Time Zone 1 finish time - Default 0 1 = Sunday Page 40
P794E Time Zone 2 day of the week - Default 0 2 = Monday Page 40
P795E Time Zone 2 start time - Default 0 3 = Tuesday Page 40
P796E Time Zone 2 finish time - Default 0 4 = Wednesday Page 40
P797E Time Zone 3 day of the week - Default 0 5 = Thursday Page 40
P798E Time Zone 3 start time - Default 0 6 = Friday Page 40
P799E Time Zone 3 finish time - Default 0 7 = Saturday Page 40
P800E Time Zone 4 day of the week - Default 0 8 = Invert time zone Page 40
P801E Time Zone 4 start time - Default 0 Times = 0000-2359 Page 40
P802E Time Zone 4 finish time - Default 0 Page 40
P803E Time Zone 5 day of the week - Default 0 Page 40
P804E Time Zone 5 start time - Default 0 Page 40
P805E Time Zone 5 finish time - Default 0 Page 40
P806E Time Zone 6 day of the week - Default 0 Page 40
P807E Time Zone 6 start time - Default 0 Page 40
P808E Time Zone 6 finish time - Default 0 Page 40
P809E Time Zone 7 day of the week - Default 0 Page 40
P810E Time Zone 7 start time - Default 0 Page 40
P811E Time Zone 7 finish time - Default 0 Page 40
P812E Time Zone 8 day of the week - Default 0 Page 40
P813E Time Zone 8 start time - Default 0 Page 40
P814E Time Zone 8 finish time - Default 0 Page 40
** Test Calls **
P815E Test calls for days of the week 1-7 Default = days 1-7 Page 51
P816E Test call time of the day Default = 2300 Page 51