Page 40 - Revision:EU-2020-10-13
C100 FREE STANDING DRAINING INSTRUCTIONS
Draining Notes
Drain the C100 Water Treatment System for transportation.
WARNING! STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbial growth).
Prior to draining the Hot Tank, turn off the Red Heater and Compressor Switch (O = OFF) and
dispense 2 litres of hot water from the C100 Water Treatment System. As hot water is
dispensed from the faucet of the unit, colder water will be introduced into the Hot
Tank. Since the Red Heater and Compressor switch is turned off, the Heater will
not energize and heat the incoming tap water. Following this precaution prevents
exposing personnel and equipment (drains, catch basin, etc.) to scalding hot water.
Red Compressor/Heater Switch must be in the O=OFF position.
Disable Cold and Hot Tanks
1. Ensure the Red Heater and Compressor Switch is off (O = OFF) to disable the Heater
and Compressor.
2. Dispense 2 litres of water through the Hot Tank to cool the water temperature in
the Hot Tank and avoid burns.
WARNING! HOT WATER. Unit produces Hot Water up to 87
o
C (189
o
F). Water above 52°C
(125°F) can cause severe burns or scalding. Hot water should be dispensed carefully into insulated
container to avoid injury.
4. Dispense cold still water to relieve any pressure built up in the system.
Drain the Cold Water Tank and Circuit
5. Remove the Lower Front Panel to
access tank feed lines.
6. Remove the Hot and Cold water supply lines from the inlet line Solenoids.