SETTINGS 9
Example - Timeclock: Softener Model Medallist 2
Capacity @ 9 lb. Salt Dosage: 25,100 Grains
Compensated Water Hardness: 19 Grains Per Gallon
Estimated Daily Water Usage: 300 Gallons Per Day
Treated Water Volume Set Point = — Water Usage
Softening Capacity 25,100 Grains
Divide by Compensated Hardness ÷ 19 Grains per Gallon
Result is total number of gallons 1,321 Gallons
of soft water per regeneration
Subtract daily Water Usage (needed — 300 Daily Water Usage (One Day Supply)
as a reserve to ensure continuous 1,021 Gallons
soft water until regeneration occurs).
Divide by daily water usage ÷ 300
3.4 Days
Round down to nearest day 3.0 Days
Set "CAP" to 3
Use the following worksheets to calculate and record the proper settings.
TreatedWaterVolumeSetPointWorkSheet-MeterModels
1. Enter Softening Capacity
2. Divide by Compensation Hardness ÷
Result is Total Gallons of Soft Water Per Regeneration =
3. Subtract Daily Water Usage (Reserve —
Result =
Round down to nearest ten for Treated Water Volume Set Point Gallons
TreatedWaterVolumeSetPointWorkSheet-TimeclockModels
1. Enter Softening Capacity
2. Divide by Compensation Hardness ÷
Result is Total Gallons of Soft Water Per Regeneration =
3. Subtract Daily Water Usage (Reserve —
4. Divide by Daily Water Usage ÷
Result =
Round down to nearest ten for days between regeneration set point Days
Note: All Softening capacity is based on new Cullex® resin and using sodium chloride as the regenerate: If potas-
sium chloride is used reduce the rated softening capacity by 20%.
Softener Capacity
Compensated Hardness