Stopping conditions and recovery steps | JetScan iFX
®
i100 scanner | 17
Condition The machine cannot
recognize the denomination and has
stopped.
This NO CALL is the top note in the pocket
and has not been included
in the count.
Action
Inspect the top note in the
pocket. Do not remove all notes from
the pocket.
To count the note, keep the note in the
pocket and then enter its denomination
using the correct denominationvaluekey
($1, $5, $10, etc.). The machine will start,
and this note will be added to the count.
To reject the note, remove the note from
the pocket and press CONT. The machine
will re-start. The removed note willnot be
added to the count.
Condition A no call occurred, and
the machine could not identify the check
MICR line.
Action Do one of the following:
•PressCHECK on the NO CALL screen
to prompt the MICR-LINE CORRECTION
screen. Red question marks denote
all unidentied characters in the MICR
line. Follow the steps on the previous
page to correct the MICR line.
•Returnthechecktothehopperfor
reprocessing and press CONT.
MICR-linecorrection–
nocallscreen
MICR-linecorrectionscreen