10 — VEHICLE CONTROL LANGUAGE (VCL)
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC
pg. 114
To add automatic fault actions to the VCL faults, the VCL programmer must dene the desired fault
actions by using the sixteen VCL variables: User_Fault_Action_01 through User_Fault_Action_16.
Each of the UserFault bits has a corre-sponding User_Fault_Action_xx variable (where “xx” is the
number of the VCL fault bit). When a VCL fault bit is set, the actions dened in the corresponding
User_Fault_Action_xx variable will be automatically executed by the operating system. For any
user fault, single or multiple actions can be specied. e available fault actions in the User_Fault_
Actions_xx variables are listed below:
Variable Fault Action
Bit0 = ShutdownMotor Disable the motor.
Bit1 = ShutdownMainContactor Shut down the main contactor (only if Main Enable = On)
Bit2 = ShutdownEMBrake Shut down the EM brake (only if EM Brake Disable Upon Fault = On).
Bit3 = ShutdownThrottle Set the Throttle_Command = 0%.
Bit4 = ShutdownInterlock Set the Interlock_State = Off.
Bit5 = ShutdownDriverl Shut down Driver1.
Bit6 = ShutdownDriver2 Shut down Driver2.
Bit7 = ShutdownDriver3 Shut down Driver3.
Bit8 = ShutdownDriver4 Shut down Driver4.
Bit9 = ShutdownPD Shut down Proportional Driver
Bit10 = FullBrake Set the Brake_Command = 100%.
Bit11 = [reserved] N/A
Bit12 = TrimDisable Disable Dual Drive trim calculation.
Bit13 = SevereDual
For Dual Drive system, one controller has a severe fault but the main contactor
must stay closed so the other controller can continue to operate.
Bit14 = ShutdownSteer Steer angle = 0°.
Bit15 = LOSDual
For Dual Drive system, set the max speed to Dual_LOS_Max_Speed
parameter for operation in Limited Operating Strategy.
e User_Fault_Action_xx variables should be set up at the beginning of a VCL program (before the
main loop) as these fault actions should be dened only once in a program. Here is another example:
User_Fault_Action_02 = 24 ;Set fault action to ShutdownInterlock
;and ShutdownThrottle
MainLoop:
if (BDI_Percentage < 10)
{
UserFault1.2 = ON ; Set User Fault bit
Put_Spy_Text(“BDI Low”) ; Send message to Model 840 display
}
else
{
UserFault1.2 = OFF ; Clear User Fault bit
}
goto MainLoop