1 — OVERVIEW
Curtis 1353 CANopen Expansion Module Manual – June 2017 Return to TOC
pg. 2
2 quadrature encoder inputs.
5V and 12V current limited power supplies.
Optional serial port, for Curtis programmer or display.
CANopen communication port controlled by two xed PDO maps and programmable over
SDOs.
CAN Node ID selectable through digital inputs or virtual digital inputs.
Soware and hardware watchdog circuits ensure proper soware operation.
IP65-rated enclosure allows the 1353 to be mounted in multiple orientations, and protects
it even in harsh environments.
Status LEDs provide external monitoring.
DESCRIPTIONS OF KEY FEATURES
High Frequency Driver Outputs
e 1353 contains nine identical output drivers. ese drivers can sink up to 3amps each through an
inductive load, with the total current limited to 18 A. Internal yback diodes to B+ prevent voltage
spikes. High frequency PWM (16 kHz) provides smooth current to the load.
Constant Current or Voltage Outputs
In Constant Current mode, the soware runs a closed loop PI controller to provide an average
constant current. This current is commanded over PDO as a 0–100% command based on the
maximum current and minimum current settings with ramping features (set through SDO or a
Curtis programmer).
Each output can also be programmed for Constant Voltage mode. In this mode, the battery
voltage is monitored and the PWM command is corrected by a feed-forward controller to provide
a constant average voltage commanded over the PDO (a 0–100% command based on the maximum
voltage setting).
In addition, each output can also be programmed to provide a directly commanded PWM% output
(Direct PWM mode) or shut o to be used as an input (Input Only mode).
Programmable Dither for Hydraulic Valves
Dither is a small variation in the command that keeps the seals of a proportional valve oiled. is
lubrication allows the valve to move freely for accurate PV control. Dither is only active on drivers
in Constant Current mode.
Min/Max Current
Max Current parameter sets the maximum allowed driver current through the load when driver
command is 100%.
Most proportional valves need a non-zero closed current in order to start opening immediately.
Min Current parameter sets the minimum driver current through the load when driver start (driver
command > 0).