7 — SERIAL COMMUNICATIONS& PROGRAMMING
pg. 47
Return to TOC Curtis 1353 CANopen Expansion Module Manual – June 2017
POWER SUPPLY MONITOR MENU
PARAMETER ALLOWABLE RANGE DESCRIPTION
Power Supply Output:
+5 V
0.0 – 6.3 V Voltage of the +5 V output.
Power Supply Output:
+12 V
0.0 – 16.0 V Voltage of the +12 V output.
Power Supply Output:
EXT Current
0 – 250 mA Combined current of the external +12 V and +5 V power supplies.
TEMPERATURE MONITOR PARAMETER
PARAMETER ALLOWABLE RANGE DESCRIPTION
Temperature -40.0 – 100.0 °C Internal temperature of the 1353.
BATTERY VOLTAGE MONITOR PARAMETER
PARAMETER ALLOWABLE RANGE DESCRIPTION
Battery Voltage 0.0 – 120.0 V Voltage of the battery.
HOUR METER MONITOR MENU
PARAMETER ALLOWABLE RANGE DESCRIPTION
Hour Meter: Hours 0 – 65535 h Present hours of the hour meter.
The hourmeter runs all the time the 1353 is powered on.
Hour Meter: Minutes 0 – 59 min Present minutes of the hour meter.
FAULT MENU
e Curtis programmer provides a convenient way to access fault information; see Section 6: Faults
and Diagnostics. e programmer displays the faults by name. It displays all faults that are currently
set and also a history of all the faults that have been set since the history log was last cleared.