Loading...
DuraCOR 311
Chapter 5 Specifications
MNL-0667-01 Rev B2
ECO-5941
Effective: 17 Mar 20
Page 37 of 72
Mounting the System
The DuraCOR 311 is mounted using 4x #10 hardware. Mounting hole locations:
Figure 23: DuraCOR 311 Mounting Hole Locations
Power
Power input: 28 VDC nominal steady state: input range 9-36VDC
MIL-STD-704F & MIL-STD-1275D compliant: steady sate voltage, ripple, surges, spikes
Power consumption: < 15 W typical
Environmental Specifications
The DuraCOR 311 is qualified to MIL-STD-810G/DO-160G:
Temperature
Operating Temperature: -40°C to +71°C (-40°F to +160°F)
Storage Temperature: -55ºC to +85ºC (-67ºF to +185ºF)