EasyManua.ls Logo

CUTES CT-2000FG Series - AC Reactor ( ACL ); Inductance of Power Side from R.S.T of Inverter(A.C.l); Wiring Diagram

CUTES CT-2000FG Series
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
3. Wiring diagram■
AC Reactor ( ACL )
The main purpose for fitting A.C.L. at the R.S.T. input side is to curb instantaneous current and to
improve ratio, it should be fitted the A.C.L. to R.S.T. input side under the following circumstance:
A. Where power system capacity is over 500KVA.
B. Using thyrister, phase advance capacity etc. for the same power supply.
Inductance of Power side from R.S.T of Inverter(A.C.L)
Voltage
(V)
Model
Current
value
(Ar.m.s)
Inductance
CT-2000FG-2-3A7 20A 0.53mH
CT-2000FG-2-5A5 30A 0.35mH
CT-2000FG-2-7A5 40A 0.26mH
CT-2000F□-2-011 60A 0.18mH
CT-2000F□-2-015 80A 0.13mH
CT-2000F□-2-022 120A 0.09mH
CT-2000F□-2-030 150A 70uH
CT-2000F□-2-037 200A 50uH
CT-2000F□-2-045 250A 44uH
CT-2000F□-2-055 300A 35uH
CT-2000F□-2-075 400A 27uH
CT-2000F□-2-093 500A 21uH
CT-2000F□-2-112 600A 21uH
CT-2000FG-2-131 600A 17 uH
220
CT-2000FG-2-150 600A 17 uH
Voltage
(V)
Model
Current
value
(Ar.m.s)
Inductance
CT-2000FG-4-3A7 10A 2.2mH
CT-2000FG-4-5A5 15A 1.42mH
CT-2000FG-4-7A5 20A 1.0mH
CT-2000F□-4 -011 30A 0.7mH
CT-2000F□-4-015 40A 0.53mH
CT-2000F□-4-022 60A 0.36mH
CT-2000F□-4-030 80A 0.26mH
CT-2000F□-4-037 100A 0.21mH
CT-2000F□-4-045 120A 0.18mH
CT-2000F□-4-055 150A 0.14mH
CT-2000F□-4-075 200A 0.11mH
CT-2000F□-4-093 250A 0.10mH
CT-2000F□-4-112 300A 70uH
CT-2000F□-4-131 300A 70uH
CT-2000FG-4-150 330A 60uH
CT-2000FG-4-188 400A 50uH
380
|
460
CT-2000FG-4-225 490A 40uH
*CT2000F□
No. Specification
G 150% load
P 120% load

Table of Contents