EasyManua.ls Logo

CUTES CT-2000FG Series - Frequency Command Limit

CUTES CT-2000FG Series
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
10. V/F control
◆V/F free pattern setting
◆Frequency command
Description: Set frequency command limit to restrict working frequency when motor is running.
Output
Frequency
Frequency
maximum
Frequency
minimum
Operation Frequency
FH
Constant
No.
Constant name Settable range Factory setting
Change during
operation
Cd51 Motor rated voltage 50.0󲕏500.0 By specification X
Cd52 Motor rated frequency (FA) 0.0 0󲕏400.00 60.0HZ X
Cd53 Maximum output frequency (FMAX) 40.00 󲕏 400.00 60.0HZ X
Cd54 Maximum output voltage (VMAX) 0.0 󲕏500.0 By specification X
Cd55 Middle output frequency (FB) 0.0 󲕏400.0 3.0HZ X
Cd56 Middle output voltage (VC) 0.0 󲕏500.0 By specification X
Cd57 Minimum output frequency (FMIN) 0.0 󲕏400.0 0.5HZ X
Cd58 Minimum output voltage (VMIN) 0.0 󲕏500.0 By specification X
Constant
No.
Constant name Settable range Factory setting
Change during
operation
Cd17 Maximum frequency 10.00󲕏400.00 60.00 X
Cd18 Minimum frequency 0.50󲕏100.00 0.00 X

Table of Contents