4. Digital Operator■
◆ LCD keypad Copy *
Press PROG+
►
Turn on Copy function then press once again to conceal
Momory 1
All Cd
A1-00
︴
A1-99
Momory 2
All CE
A2-04
︴
A2-99
Momory 3
All Cd &CE
A3-00
︴
A3-99
CE
A4-04
︴
A4-99
Memory allocation diagram
Constant information:
NO Function Detail of Data Initial Factory Setting
CC-00 Copy mode
0: Standard mode
1: Reserved
2: Modify Cd and CE on Keypad
3: Copy Cd from Control PCB to Memory 1 of Keypad
4: Copy CE from Control PCB to Memory 2 of Keypad
5: Copy Cd & CE from Control PCB to Memory 3 of Keypad
6: Write Cd (Memory 1) to Control PCB
7: Write CE (Memory 2) to Control PCB
8: Write Cd & CE (Memory 3) to Control PCB
0
※LCD keypad Copy under development