DVG-7111S User’s Manual VoIP Router Configuration-IVR
D-Link Systems, Inc. 87
a new IP address) enter 192*168*1*2 (new IP address).
Save Settings
When all setting procedures are completed, dial 509 (Save Settings) from phone keypad. Wait for about
three seconds, you should hear a voice prompt “1 (one).” You can now hang up the phone and please
reboot the VoIP TA to enable the new settings.
To inquire about the current VoIP TA WAN Port IP address setting
After completing all your settings, dial 101 from the keypad, then you can hear the system play back the
current WAN Port IP address. If the system does not play back the IP address after dialing 101, this
indicates that the VoIP TA currently is not connected to the Internet. Please check and make sure the
cable connections, account numbers, and passwords are correct.
4-1-1 IVR Functions Table:
WAN Port IP address Set/Query
Dial function code 114 and then dial
1 for a Static IP connection then
setup the IP address.
WAN Port Subnet Mask Set/Query
WAN Port Default Gateway Set/Query
Current Network IP Access Set/Query (1: Static IP, 2: DHCP, 3: PPPoE)
Phone Book manager IP address Set/Query
Set/Query whether or not to use a Public Telephone Book
(0: Disable 1: Enable)
Set/Query whether or not this VoIP TA acts as the Phone Book manager
(0: Disable 1: Enable)
Querying the connection to Phone Book manager
Dial function code 114 and then dial
3 for a PPPoE connection.
Uses NAT (0: Disable 1: Enable)
LAN Port Subnet Mask Set/Query
Restore factory default IP address configuration
A static IP address for WAN Port
IP:192.168.1.2
Mask:255.255.255.0
Gateway:192.168.1.254
Restore factory default settings
Set the IVR and the language used on the Web GUI
(1: English, 2: Traditional Chinese, 3: Simplified Chinese)