149
Array was incomplete due to
missing NV Watermark
RAID migration was interrupted by a
shutdown. If array is online, try migration
again. If array is offline, delete and
recreate array.
Rebuild
Corrective Action
Rebuild is started
Result of settings or user action. Normal.
Rebuild is completed
Normal.
Rebuild is paused
Rebuild paused because of user
intervention, schedule or a higher priority
background activity.
Rebuild is resumed
Rebuild has resumed again after a
pause.
Rebuild is stopped
Rebuild stopped because of user
intervention, schedule or the logical drive
was deleted or the target disk drive
encountered an error. If rebuild stopped
by the user, restart the rebuild.
Rebuild stopped internally
The logical drive is offline.
Rebuild is aborted due to an
internal error.
System resources are low. Reduce
system load or restart the NAS.
Rebuild is queued
Rebuild has been set manually or by
schedule.
Rebuild marks logical drive
synchronized upon rebuild
completion
Result of successful rebuild. Normal.
Redundancy Check
Corrective Action
Redundancy Check is started
Redundancy Check has started
manually or by schedule.
Redundancy Check is
completed
Redundancy Check has finished.
Redundancy Check is paused
Redundancy Check paused because of
user intervention, schedule or a higher
priority background activity.
Redundancy Check is
resumed
Redundancy Check has resumed again
after a pause.
Redundancy Check is stopped
Redundancy Check stopped because of
user intervention, schedule or the logical
drive was deleted or went critical or
offline.
Redundancy Check is aborted
System resources are low. Reduce

Table of Contents