ISTRUZIONI PER L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCTIONS DE MISE EN SERVICE ET D'ENTRETIEN
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE
INSTALLATIONSANWEISUNG UND WARTUNG
INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD
INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO
INSTALLATIONS - OCH UNDERHÅLLSANVISNING
ИНСТРУКЦИИ ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ
INSTRUKCJE INSTALACJI I KONSERWACJI
ES 1 M - ES 3 M - ES 0,75 T - ES 1 T - ES 1,5 T - ES 3 T
ES 4 T - ES 7,5 T - ES 10 T - ES 12,5 T - ES 15 T
ES 20 T - ES 25 T - ES 30 T - ES 40 T
ES 7,5 T SD - ES 10 T SD - ES 12,5 T SD - ES 15 T SD
ES 20 T SD - ES 25 T SD - ES 30 T SD - ES 40 T SD

Table of Contents

Questions and Answers

  • A
    Angel CooperAug 5, 2025
    Why is the DAB ES 1 M Controller motor not fed?
    • M
      Matthew DelgadoAug 5, 2025
      The DAB Controller motor may not be fed due to several reasons: the control box protection or differential switch has tripped (check pump cable insulation and reset the protection); there's no voltage on terminals L1-N (check panel cables and switches); the internal transformer protection has tripped (reset by turning off the main switch for three minutes, identify any short circuits); the remote control switch vibrates (supply voltage is insufficient); or there's a fault in the input B connection (remove the fault in the electric connections).
  • S
    Susan GomezAug 11, 2025
    What to do if the DAB Controller protection intervenes?
    • C
      Charles LiAug 11, 2025
      If the DAB Controller protection activates, it could be due to a blocked pump impeller (perform maintenance to free it), excessive motor absorption at full load (line voltage outside +/- 10% limits, or bearings need maintenance), or a faulty overload protection (replace the component or control unit).
  • H
    Heather JohnsonAug 17, 2025
    What to do if the DAB Controller pump continues delivering and doesn't respond to external commands?
    • E
      Edward BarberAug 17, 2025
      If the DAB Controller pump continues delivering and doesn't respond to external commands, the pressure switch, level switch, or other device might not be correctly connected to the control unit. Ensure these are correctly connected and check the system operation. If the problem persists, consider replacing the component.
  • M
    Megan ScottAug 23, 2025
    What to do if the DAB ES 1 M pump doesn't deliver, the motor doesn't start, and the lamps HL2 is lit but HL3 is off?
    • M
      Mr. John StaffordAug 23, 2025
      If the DAB Controller pump isn't delivering, the motor isn't starting, HL2 is lit, and HL3 is off, it could be due to several reasons: * The electro-probe circuit is inefficient (resistance > 80 k ohm) - change the connections or the electro-probe itself; insert the common electro-probe connected to terminal 18 if the water isn't directly in contact with the earth system. * The electro-probe isn't immersed in water - position it under the water level. * The input remote control circuit at terminals B is open - close the contacts, and check the pressure/level switch. * The microswitch SP1 isn't correctly positioned - position it depending on the number of electro-probes used. * The module M2S is faulty - replace it.
  • C
    clairebeckAug 29, 2025
    How to fix a DAB ES 1 M remote alarm that is not working?
    • L
      Lisa RobinsonAug 29, 2025
      If the DAB Controller remote alarm isn't working, check that the connections correspond to the proposed diagram and make sure that the acoustic or luminous warnings are efficient. If not, change the component.

Summary

ES 1 M - ES 3 M Series

Technical Data ES 1 M-ES 3 M

Specifications, operating limits, and environmental conditions for ES 1M-ES 3M.

Wiring Diagram Interpretation ES 1 M-ES 3 M

Explanation of wiring references and control components for ES 1M-ES 3M.

Electric Connections ES 1 M-ES 3 M

Instructions and safety for electrical connections for ES 1M-ES 3M.

Electro-Probe Connection

Procedure for connecting electro-probes to the system.

Control Box Connection

Steps to connect the panel to the control box for submerged pumps.

Starting the System

Procedure for initial startup and operation of the electropump system.

Alarm System Operation

Description of alarm indications and system behavior during alarms.

Troubleshooting ES 1 M-ES 3 M

Faults, causes, and remedies for the ES 1M-ES 3M series.

Spare Parts List ES 1 M-ES 3 M

List of replacement parts with reference codes and models.

Comprehensive Pump Series Information

Technical Data for Multiple Pump Series

Technical specifications for ES 0.75 T to ES 40 T and SD models.

Wiring Diagram Interpretation for Multiple Series

Explanation of wiring diagram references for various pump models.

Electrical Connections Guide

Instructions for safe electrical connections and fuse selection.

Electro-Probe Connection Procedures

Detailed instructions for connecting electro-probes to pump systems.

System Startup Procedures

Steps for safely starting up and operating pump systems.

Alarm System Functionality

Information on alarm indications, testing, and reset procedures.

Troubleshooting for Various Pump Series

Guidance on diagnosing and resolving issues across multiple ES pump models.

Spare Parts Identification

List of spare parts for various ES pump models with codes.

Product Dimensions and Specifications

Product Dimensions and Model Specifications

Table detailing physical dimensions (A-E) for various pump models.

DAB ES 1 M Specifications

General IconGeneral
BrandDAB
ModelES 1 M
CategoryController
LanguageEnglish