17
* Note) In Function mode, if the value of F-13 is set the Base Offset (page26) , the
comparative output operates as follows.
1) Decision mode : Measured Value (Offset-Lower limit setup value) RY1 ON (Low)
Measured Value (Offset +Upper limit setup value) RY3 ON (Hi)
(Offset -
Lower limit setup value) < Measured value < (Offset +Upper limit setup value) RY2 ON (OK)
2) High limit mode : Measured Value (Offset +RY1 setup value) RY1 ON
Measured Value (Offset +RY2 setup value) RY2 ON
Measured Value (Offset +RY3 setup value) RY3 ON
Measured Value (Offset +RY4 setup value) RY4 ON
Measured Value <(Offset + RY1 setup value) – Hysteresis value RY1 OFF
Measured Value< (Offset +RY2 setup value) - Hysteresis value RY2 OFF
Measured Value < (Offset +RY3 setup value) – Hysteresis value RY3 OFF
Measured Value< (Offset +RY4 setup value) - Hysteresis value RY4OFF
3) Low limit mode : Measured Value (Offset +RY1 setup value) RY1 ON
Measured Value (Offset +RY2 setup value) RY2 ON
Measured Value (Offset +RY3 setup value) RY3 ON
Measured Value (Offset +RY4 setup value) RY4 ON
Measured Value > (Offset +RY1 setup value) + Hysteresis value RY1 OFF
Measured Value > (Offset +RY2 setup value) + Hysteresis value RY2 OFF
Measured Value > (Offset +RY3 setup value) + Hysteresis value RY3 OFF
Measured Value > (Offset +RY4 setup value) + Hysteresis value
RY4 OFF
4) Low & High limit mode
Measured Value (Offset +RY1 setup value) RY1 ON
Measured Value (Offset +RY2 setup value) RY2 ON
Measured Value (Offset +RY3 setup value) RY3 ON
Measured Value (Offset +RY4 setup value) RY4 ON
Measured Value > (Offset +RY1 setup value) + Hysteresis value RY1 OFF
Measured Value > (Offset +RY2 setup value )+ Hysteresis value RY2 OFF
Measured Value <(Offset + RY3 setup value) - Hysteresis value RY3 OFF
Measured Value < (Offset +RY4 setup value) - Hysteresis value RY4 OFF