3
2 Connection and Installation
Cable Connections
The access controller needs to be connected to devices like sirens, readers, and door contacts.
Table 2-1 Port description
Port Cable color Cable name Description
CON1
Black RD– Negative electrode of external card reader.
Red RD+ Positive electrode of external card reader.
Blue CASE Tamper alarm input of the external card reader.
White D1
Wiegand D1 input (connected to external card
reader)/output (connected to controller).
Green D0
Wiegand D0 input (connected to external card
reader)/output (connected to controller).
Brown LED Connected to external reader indicator in
Yellow B
RS-485 negative electrode input
external card reader)/output (connected to controller,
or connected to door control security module).
If the security module is enabled, you need to
purchase access control security module
separately. The security module
power supply to provide power.
Once the security module is enabled, the exit
button, lock control and firefighting linkage will
be invalid.
Purple A
RS-485 positive electrode input (connected to external
card reader)/output (connected to controller
connected to door control security module).
If the security module is enabled, you need to
purchase access control security module
separately. The security module needs separate
power supply to provide power.
Once the security module is
button, lock control and firefighting linkage will
be invalid.
CON2
red
ALARM1_NO Alarm 1 normally open output port.
orange
ALARM1_CO
M
Alarm 1 common output port.
blue
ALARM2_NO Alarm 2 normally open output port.
ALARM2_CO Alarm 2 common output port.