43
Modifying alarm linkage parameter
Table 4-1 Alarm linkage parameter description
Parameter Description
Alarm Input You cannot modify the value. Keep it default.
Name Enter a zone name.
Alarm Input Type
There are two options: NO and NC.
If alarm input type of the alarm device you purchased is NO, then you
should select NO; otherwise you should select NC.
Fire Link Enable
If fire link is enabled the access controller will output alarms when fire
alarms are triggered. The alarm details will be displayed in the alarm log.
Alarm output and access link are NO by default if fire link is enabled.
Alarm Output
Enable
The relay can output alarm information (will be sent to the management
platform) if the Alarm Output is enabled.
Duration (Sec.) The alarm duration, and the range is 1–300 seconds.
Alarm Output
Channel
You can select an alarm output channel according to the alarming device
that you have installed. Each alarm device can be regarded as a channel.
Access Link Enable
After the Access Link is enabled, the access controller will be normally on
or normally closed when there are input alarm signals.
Channel Type There are two options: NO and NC.
Click OK, and then the configuration is completed.
The configuration on the web will be synchronized with the configuration in the client if the access
controller is added to a client.