7 Installation
Installer reference guide
30
ERLQ004~008CAV3 + EHBH/X04+08CA
Daikin Altherma - Low Temperature Split
4P313774-1C – 2012.11
283 mm
580 mm
7.2.4 To prevent the outdoor unit from falling
over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1 Prepare 2 cables as indicated in the following illustration (field
supply).
2 Place the 2 cables over the outdoor unit.
3 Insert a rubber sheet between the cables and the outdoor unit
to prevent the cable from scratching the paint (field supply).
4 Attach the cable’s ends. Tighten those ends.
7.3 Mounting the indoor unit
7.3.1 To install the indoor unit
CAUTION
Do NOT grasp the piping to lift the indoor unit.
1 Lift the unit from the package.
60kg
1
2
Remove the 4 screws from the bottom of the unit. Unhook and
remove the side plates.
4x
1
2
3
3
3 Put the installation pattern (see packing) on the wall and follow
the steps as shown below.
2x
21 3 4
4 Lift the unit.
1
2
5 Tilt the top of the unit against the wall at the position of the 2
inserted screws.
6 Hook the unit against the wall.