4 About the units and options
Installer reference guide
7
ERLQ004~008CAV3 + EHBH/X04+08CA
Daikin Altherma - Low Temperature Split
4P313774-1C – 2012.11
a General safety precautions
b Addendum book for optional equipment
c Indoor unit installation manual
d Operation manual
e CD/DVD
f User interface kit: user interface, 4 fixing screws, 2
plugs
g Shut-off valve
h User interface cover
i Top plate of indoor unit
j Screws
4 About the units and options
4.1 Identification
NOTICE
When installing or servicing several units at the same time,
make sure NOT to switch the service panels between
different models.
4.1.1 Identification label: Outdoor unit
Location
Model identification
Example: ER L Q 006 CA V3
Code Explanation
ER European split outdoor pair heat pump
L Low water temperature – ambient zone:
L=−10~−20°C
Q Refrigerant R410A
006 Capacity class:
▪ 004=4.5 kW
▪ 006=6 kW
▪ 008=7.5 kW
CA Series
V3 V3=1~, 230 V, 50 Hz
4.1.2 Identification label: Indoor unit
Location
Model identification
Example: E HB H 04 CA 3V
Code Description
E European model
HB HB=Wall-mounted indoor unit
H ▪ H=Heating only
▪ X=Heating/cooling
04 Capacity class:
▪ 04=4 kW
▪ 08=8 kW
▪ 16=16 kW
CA Series
3V Backup heater model
▪ 3V
▪ 9W
4.2 Possible combinations of units and
options
4.2.1 List of options for outdoor unit
Drain pan (EKDP008CA)
The drain pan is required to gather the drain from the outdoor unit.
The drain pan kit consists of:
▪ Drain pan
▪ Installation brackets
For installation instructions, see the installation manual of the drain
pan.
Drain pan heater (EKDPH008CA)
The drain pan heater is required to avoid freezing-up of the drain
pan.