EasyManuals Logo

Daikin FTY35GXV1 User Manual

Daikin FTY35GXV1
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
SiBE01-829 Functions
Functions and Control 17
1.4 Automatic Operation
Outline When the automatic mode is selected with the remote controller, the microcomputer determines
the operation mode from cooling and heating according to the room temperature and the
setpoint.
The unit automatically switches the operation mode to cooling or heating to maintain the room
temperature.
Details of the
Control
Target temperature equals setpoint plus correction value (cooling:0
°
C, heating: –1.5
°
C)
Mode switching point and operation ON/OFF point are as follows.
Cooling
Heating: Room temperature – setpoint
<
4
°
C
Heating
Cooling: Room temperature – setpoint
>
+
3
°
C
Cooling thermostat ON : Room temperature – setpoint
>
+
0.5
°
C
Cooling thermostat OFF: Room temperature – setpoint
<
1
°
C
Heating thermostat ON : Room temperature – setpoint
<
3.5
°
C
Heating thermostat OFF: Room temperature – setpoint
>
1
°
C
HeatingCooling
Cooling thermostat ON
+3°C
+0.5°C
–1°C
–3.5°C
–4°C
Cooling/Heating thermostat OFF
Cooling
Heating
Cooling
Compressor ON
Compressor OFF
(R8642)
CoolingHeating
Heating thermostat ON
Room temperature – setpoint

Table of Contents

Other manuals for Daikin FTY35GXV1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTY35GXV1 and is the answer not in the manual?

Daikin FTY35GXV1 Specifications

General IconGeneral
BrandDaikin
ModelFTY35GXV1
CategoryAir Conditioner
LanguageEnglish

Related product manuals