EasyManuals Logo

Daikin FTY35GXV1 User Manual

Daikin FTY35GXV1
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
SiBE01-829 Functions
Functions and Control 21
1.7 POWERFUL Operation
Outline In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed.
Details of the
Control
When POWERFUL button is pushed, the fan speed and the target temperature will be
converted to the following states for 20 minutes.
Ex.) : POWERFUL operation in cooling mode.
Operation mode Fan speed Target temperature
Cooling HH tap Set temp. –2°C
Heating HH tap Set temp. +2°C
(R8643)
Target temp.
Fan
Set temp.
Set temp. –2˚C
POWERFUL ON
POWERFUL OFF
HH tap
Set tap
It counts 20 min. also in the remote controller.
Ending condition: "or" in 1 to 4
1. After the lapse of 20 minutes.
2.
POWERFUL operation is OFF.
3. Operation halts.
4. Thermostat OFF
20min.

Table of Contents

Other manuals for Daikin FTY35GXV1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTY35GXV1 and is the answer not in the manual?

Daikin FTY35GXV1 Specifications

General IconGeneral
BrandDaikin
ModelFTY35GXV1
CategoryAir Conditioner
LanguageEnglish

Related product manuals