2.1 Main specifications
Model
Item
LXE10E
Condenser cooling system Air cooled type
Controller
DECOS3d
Power supply AC 3-phase 380V/400V/415V 50Hz, 440V/460V 60Hz
Compressor Hermetic scroll type (Motor output: 5.5kW)
Evaporator Cross fin coil type
Air-cooled condenser Cross fin coil type
Evaporator fan Propeller fan
Evaporator fan motor Three-phase squirrel-cage induction motor
Condenser fan Propeller fan
Condenser fan motor Three-phase squirrel-cage induction motor
Defrosting
Hot-gas defrosting system
Dual timer, on-demand defrost and manual switch
Detecting the temperature of evaporator outlet pipe and return air
Electronic expansion valve
Capacity control
Capacity control with hot gas bypass and suction modulating valve
Protective devices
/Safety devices
Circuit breaker, PT/CT board (for over current protection).
Condenser fan-motor thermal protector
Evaporator fan-motor thermal protector
High-pressure switch, Fusible plug, Fuse (10A, 5A)
Refrigerant (charged amount) R134a : 4.6 (kg)
Refrigerant oil (charged amount)
IDEMITSU, Daphne hermetic oil FVC 46D : 2.2(R)
Weight
Note; Refer to each model's specification for detail weight of
each model.
System
Initiation
Termination
Refrigerant flow control
Compressor thermal protector