If this happens Check How to resolve
Crackling, buzzing, and
fi zzes sounds are audible
during operation.
Is the UNIT1 set securely?
Securely set it.
Page 18.
Has dust accumulated on the ionized wires of the
ionizing frame?
Clean it.
Page 33, 34.
A hissing sound heard from UNIT2 during operation.
There is nothing wrong with the unit.
-
Odor is coming from the
air outlet.
Is a large amount of odor being generated
temporarily? (Many people smoking or grilling meat.)
If operated, the odor will gradually go away.
Have you moved the main unit to another room?
Odor from the original room may smell.
Let the unit run for a while.
Are the pre-fi lter, pleated fi lter, UNIT1 and/or
humidifying fi lter dirty?
Clean it.
Page 29-36.
Are odors constantly being generated in the room (i.e.,
paint, new furniture, wall paper, sprays, cosmetics,
chemicals, etc.)?
Ventilate the room or let the unit run with air fl ow
promoted in the room.
The “UNIT1” lamp does
not go out or immediately
lights again, despite
having cleaned that UNIT1
(plasma ionizer).
Is the UNIT1 set securely?
Securely set it.
Page 18.
Are not droplets left in the opposing pole plates or
other places?
Completely dry UNIT1 after cleaning it.
Are not bits of lint left in the UNIT1? Remove all lint.
Was UNIT1 inadequately rinsed after cleaning with a
cleaner?
Remove any remaining cleaner.
Page 33, 34.
Are not the ionized wires cut?
Check the ionized wires.
Page 34.
If broken, they need replacing, therefore contact the
service shop.
Humidity does not rise.
Is the room too big?
Use the unit in an appropriately sized room.
Is indoor temperature low with the walls and fl oor dry?
Humidity does not readily rise if the indoor temperature
is low, and the walls and fl oor are dry. Watch the
situation for 1 - 2 weeks to see if humidity rises.
Is air fl ow set to a low rate?
Set “CONT” for the humidify setting and increase the
air fl ow rate setting.
If the problem cannot be corrected after taking the above action, contact the service shop.