EasyManuals Logo

Dalsa Spyder 3 S3-10-01k40-00-R User Manual

Dalsa Spyder 3 S3-10-01k40-00-R
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
62 PRELIMINARY Spyder 3 CL User's Manual
03-032-20008-03 DALSA
Digital Signal Processing
To optimize camera performance, digital signal processing should be completed after any
analog adjustments.
FPN Correction
Performing FPN Correction
Syntax: Performs FPN correction and eliminates FPN noise by removing
individual pixel dark current.
Syntax:
ccf
Notes:
Perform all analog and digital adjustments before
performing FPN correction.
Perform FPN correction before PRNU correction.
Refer to
Calibrating the Camera to Remove Non-Uniformity
(Flat Field Correction) on page
59 for a procedural overview
on performing flat field correction.
To save FPN coefficients after calibration, use the
wfc
command. Refer to section
7.9 Saving and Restoring PRNU
and FPN Coefficients for details.
Related Commands:
ccp, wfc
Example:
ccf
Setting a Pixel’s FPN Coefficient
Purpose: Sets an individual pixel’s FPN coefficient.
Syntax
sfc x i
Syntax Elements:
x
The pixel number from 1 to sensor pixel count.
i
Coefficient value in a range from 0 to 2047 (12 bit LSB).
Example:
sfc 10 50

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dalsa Spyder 3 S3-10-01k40-00-R and is the answer not in the manual?

Dalsa Spyder 3 S3-10-01k40-00-R Specifications

General IconGeneral
BrandDalsa
ModelSpyder 3 S3-10-01k40-00-R
CategoryColor Camera
LanguageEnglish