65 Spyder2 User’s Manual
03-032-10091-06 Teledyne DALSA
Code Command Short
Form
Parameters Description
34 set_netmessage_mode
snm i
Enabl e/ di sabl e camera
messages unr elated to the
executed netw ork command:
0: Enable messages, defaul t
1
: Disable messages
35 set_pr etri gger
sp i
Set the pr etrigger to a val ue
from
0
to
15
.
36 set_pr nu_coeff
spc i i
Set the PRN U coeffici ent. The
first par ameter is the pi xel
number within the range 1 to
the sensor pi xel count. The
second parameter i s a
specified value within the
range
0
to
511
.
37 set_subtract_background
ssb t i
Subtracts the input value from
the output signal. The first
parameter i s the tap selection
either 1 or 0 for all taps. The
second parameter i s the
subtr acted value in a range
from
0
to
511
.
38 set_sync_frequency
ssf i
Sets the line r ate, i n exposure
mode 2, to a val ue fr om
1000H z to camera's maximum
li ne r ate. Val ue rounded
up/ down as required.
39 set_system_gain
ssg t i
Set the digital gain. The first
parameter i s the tap selection
either 1 or 0 for all taps. The
second parameter is a gai n
value is specified from 0 to
511.
40 set_upper_threshold
sut i
Set upper threshold to a value
from 0 to 255 in 8-bit data
modes, and 0 to 1023 i n 10-
bit.
41 set_video_mode
svm i
Sw i tch betw een cal i brated and
uncal i brated modes:
0: Uncalibrated video,
deactivate video correction
1: Calibrated video, acti vated
correction
2
: Test pattern
42 verify_temperatur e
vt
Check the internal
temperature of the camer a.
43 verify_voltage
vv
Check the camera voltages and
return OK or fail.