Mnemonic Syntax Parameters
Description
set exposure time
set
f
Sets the exposure time. Refer to the
camera help screen (h command) for
allowable range.
set fpn coeff
sfc
x i
Set the FPN coefficient.
x =pixel number within the range 1 to
sensor pixel count.
i= FPN value within the range 0 to
2047 (12-bit LSB).
set GPIO input
sgi
i1 i2
Sets the GPIO input signal.
i1 = input number in a range from 0 to
3
i2 = signal to use where:
0 = disabled
1 = TTL
2 = LVDS
Note: sgi 3 2 is not available.
set GPIO output
sgo
i1 i2
Sets the GPIO output signal.
i1 = output number in a range from 0
to 3
i2 = output signal to use where:
0 = disabled
1 = TTL
2 = LVDS
PUT NOTE here that sgi 3 2 is not
available
set lower threshold
slt
i
The pixels below the lower threshold
are checked for and reported in the
end-of-line sequence in a range from 0-
4095.
set prnu coeff
spc
x i
Set the PRNU coefficient.
x=pixel number within the range 1 to
sensor pixel count.
i= PRNU value within the range 0 to
28671.
set readout mode
srm
i
Set the readout mode in order to clear
out dark current charge in the vertical
transfer gates before the sensor is read
out.
0 = Auto.
1 = Dark current clear.
2 = Immediate readout. Does not clear
dark current.
set subtract background
ssb
t i
Subtract the input value from the
output signal.
t = Tap value. 0 for all taps or 1 to
number of camera taps for individual tap
selection.
i = Subtracted value in a range from 0
to 4095.