When the self-protection state is active, a buzzer will sound every other minute, the ALARM indicator will flash,
and the display indicates an error code and the water temperature alternatively. Press CANCEL for 3 seconds
to stop the alarm. When the protection cause is resolved the error code disappears on the display, the buzzer
sound stops, and the unit returns to normal operation.
Examples of problems that can trigger the self-protection function:
o
The air inlet or outlet is blocked
o
The evaporator is covered with too much dust.
o
Incorrect power supply (exceeding the range of 220-240V AC)
If the unit does not start automatically after the problem has been resolved, the user can reset the self-protec-
tive function by shutting down the power supply manually and then restart the system again.
11.4.6 Water temperature display
The temperature on the display is only showing the water temperature in the upper part of the water tank
(over 1/4), that is, the water you will be using.
The 6 LED indicators beside the water temperature on the display indicate the level of the water temperature
in the lower part of the tank. When the temperature reaches 40°C, the blue one is lit; when it reaches 50°C, the
blue and yellow ones are lit; when it reaches 60°C, the blue, yellow, and red ones are lit.
When hot water is tapped, the temperature in the lower part of the tank may decrease while the upper part
still keeps a high temperature. The system will then start heating the lower part in the tank. This is normal
behaviour.
11.4.7 Trouble shooting
If errors occur, the system enters a standby mode. It could still work, but not so efficiently as normal. Contact
service technician for corrective actions.
If a critical error occurs, the system will not work at all. Contact service technician for corrective actions.
If an error occurs, the buzzer will sound every other minute, a warning light will be flashing, the display will
show the error code and water temperature alternatively. To stop the alarm, press the CANCEL key for 3 sec-
onds. Contact service technician for corrective actions
11.4.8 Heat up time
Figure 17. Heat-up time from 15 °C water starting temperature
Position Explanation
1 Time (h)
2 Ambient temperature (°C)
Installation, Service and User Manual VMGFK202 – 31