13
VIFZL35X © Danfoss 04/2011
Installation Guide Danfoss Link™ HC
GB
Degraded mode The actuator will be activated with a 25% duty cycle, if the signal from the
room thermostat is lost.
Flashing output /
alarm LED(s)
Output or actuator is short-circuited or the actuator is disconnected.
Technical specifications
Transmission Frequency 862.42 Mhz
Transmission range in normal constructions up to 30 m
Transmission power < 1 mW
Supply voltage 230 VAC, 50 Hz
Actuator outputs 10 x 24 VDC
Max. continued output load (total) 35 VA
Relays 230 VAC / 8 (2) A
Ambient temperature 0 - 50°C
IP class 30
Disposal instructions
Trouble shooting