the return filter must be sized to suit the max. return oil flow. Pressure filters must be fitted to suit max.
pump oil flow.
Internal filters
The filters built into PVG 32 are not intended to filter the system but to protect important components
against large particles. Such particles can appear in the system as a result of pump damage, hose fracture,
use of quick-couplings, filter damage, starting up, contamination, etc. The filter in the electrical actuator
PVE protecting the solenoid valves has a mesh of 150 µm. Bursting pressure drop for internal filters is 25
bar [360 psi].
Technical Information
PVG 32 Proportional Valve Group
Other operating conditions
48 |
©
Danfoss | August 2017 520L0344 | BC00000038en-US0802

Table of Contents

Other manuals for Danfoss PVG 32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVG 32 and is the answer not in the manual?

Danfoss PVG 32 Specifications

General IconGeneral
CategoryControl Unit
Maximum working pressure350 bar
Size32
TypeProportional Valve
Maximum operating pressure420 bar
Porting patternISO 4401
Electrical connectionAMP