3.4  Commissioning (RF models only) 
If the thermostat and the receiver have been supplied together in 
a combined pack, the units have been paired in the factory and no 
commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal, follow steps 
1-5 below. 
Step 1  TP5001-RF
Reset the unit by pressing the recessed reset 
button.
Step 2  Press and hold V and + buttons for 
3 seconds (TP5001-RF now transmits unique 
signal continuously for 3 minutes).
Step 3  RX1
Press and hold buttons PROG and CH1 for 3 seconds until green light 
 ashes once.
Step 4  RX2 (if applicable)
Stat 1 - perform steps 1-3 and 5. 
Stat 2 - perform steps 1-2 and then press 
PROG and CH2 on RX2.
RX3  (if applicable) 
Stat 1 - perform steps 1-3 and 5.
Stat 2 - perform steps 1-2 and then press PROG and CH2 on RX3 then 
step 5.
Stat 3 - perform steps 1-2 and then press PROG and CH3 on RX3.
Step 5  TP5001-RF
Press V or Λ  to select temperature - the unit will revert back to operating 
mode. 
4.0  Installer Advanced Programming Options
TP5001 incorporates a number of advanced features which can be set by the 
user. These are accessed via a User Advanced Programming Mode, please 
refer to User Advanced Programming in the user instructions for details.
TP5001 incorporates an additional number of advanced features which can be 
set by the installer to improve the operating e  ciency of the system and where 
required, to change the user functionality of the product. These are accessed 
via an Installer Advanced Programming Mode. These settings are optional and 
need only be made if there is a demand for the enhanced functions.