Loading...
Synchronizing controller
MG.10.N4.02 - VLT is a registered Danfoss trademark 75
User setting: __________ quad counts
Synchronous operation; Program 2:
Hold speed
Factory setting: 10%
Setting range from: 0 to: 100 %
User setting: __________ %
728
Test run, program 1:
Synchronizing type (Sync type)
Factory setting: 0
Setting range from: 0 to: 1
User setting: __________
Synchronous operation; Program 2:
Delta hold speed
Factory setting: 5 %
Setting range from: 1 to: 100%
User setting: __________ %
729
Test run, program 1:
Activate feed forward and PID calculation (FFVEL calc.).
Factory setting: 0
Setting range from: 0 to: 2
User setting: __________
Synchronous operation; Program 2:
Home function
Factory setting: 0
Setting range from: 0 to: 2
User setting: __________
730
Test run, program 1:
Encoder velocity (Encoder RPM).
Factory setting: 1500
Setting range from: 1 to: 65000 RPM
User setting: __________ RPM
Synchronous operation; Program 2:
Home speed
Factory setting: 10 %
Setting range from: 1 to: 100 %
User setting: __________ %
731 Home acceleration
Factory setting: 10 %
Setting range from: 1 to: 200 %
User setting: __________ %