Loading...
Normal overload 110% for 1 minute
Size: PK75 P1K1 P1K5 P2K2 P3K0 P3K7 P4K0 P5K5 P7K5 P11K P15K P18K P22K P30K P37K P45K P55K P75K P90K
Typical Shaft Output [kW] 0.75 1.1 1.5 2.2 3 3.7 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90
Output current
IP 20 / NEMA Chassis A2A2A2A2A2A2A2A3A3B3B3B3B4B4B4C3 C3C4C4
IP 21 / NEMA 1 A2 A2 A2 A2 A2 A2 A2 A3 A3 B1 B1 B1 B2 B2 B2 C1 C1 C2 C2
IP 55 / NEMA 12 A5 A5 A5 A5 A5 A5 A5 A5 A5 B1 B1 B1 B2 B2 B2 C1 C1 C2 C2
IP 66 / NEMA 12 A5 A5 A5 A5 A5 A5 A5 A5 A5 B1 B1 B1 B2 B2 B2 C1 C1 C2 C2
Continuous
(3 x 525-550 V ) [A]
1.8 2.6 2.9 4.1 5.2 - 6.4 9.5 11.5 19 23 28 36 43 54 65 87 105 137
Intermittent
(3 x 525-550 V ) [A]
2.9 3.2 4.5 5.7 - 7.0 10.5 12.7 21 25 31 40 47 59 72 96 116 151
Continuous
(3 x 525-600 V ) [A]
1.7 2.4 2.7 3.9 4.9 - 6.1 9.0 11.0 18 22 27 34 41 52 62 83 100 131
Intermittent
(3 x 525-600 V ) [A]
2.6 3.0 4.3 5.4 - 6.7 9.9 12.1 20 24 30 37 45 57 68 91 110 144
Continuous kVA (525 V AC)
[kVA]
1.7 2.5 2.8 3.9 5.0 - 6.1 9.0 11.0 18.1 21.9 26.7 34.3 41 51.4 61.9 82.9 100 130.5
Continuous kVA (575 V AC)
[kVA]
1.7 2.4 2.7 3.9 4.9 - 6.1 9.0 11.0 17.9 21.9 26.9 33.9 40.8 51.8 61.7 82.7 99.6 130.5
Max. cable size
(mains, motor, brake)
[AWG]
2)
[mm
2
]
-
24 - 10 AWG
0.2 - 4
6
16
2
35
1
50
3/0
95
5)
Max. input current
Continuous
(3 x 525-600 V ) [A]
1.7 2.4 2.7 4.1 5.2 - 5.8 8.6 10.4 17.2 20.9 25.4 32.7 39 49 59 78.9 95.3 124.3
Intermittent
(3 x 525-600 V ) [A]
2.7 3.0 4.5 5.7 - 6.4 9.5 11.5 19 23 28 36 43 54 65 87 105 137
Max. pre-fuses
1)
[A]
10 10 10 20 20 - 20 32 32
Environment:
Estimated power loss
at rated max. load [W]
4)
35 50 65 92 122 - 145 195 261 225 285 329
Enclosure IP 20:
Weight
enclosure IP20 [kg]
6.5 6.5 6.5 6.5 6.5 - 6.5 6.6 6.6 12 12 12 23.5 23.5 23.5 35 35 50 50
Efficiency
4)
0.97 0.97 0.97 0.97 0.97 - 0.97 0.97 0.97 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98
Table 10.1:
5)
Motor and mains cable: 300MCM/150mm
2
10.1.4. Mains Supply 3 x 525 - 600 VAC
10. Specifications
VLT
®
AQUA Drive
Operating Instructions
142
MG.20.M4.02 - VLT
®
is a registered Danfoss trademark
10

Table of Contents