16-37 Inv. Max. Current
Range: Function:
motor. The data are used for
calculation of torque, motor
protection, etc.
16-38 SL Controller State
Range: Function:
0 * [0 - 100 ] View the state of the event under execution by
the SL controller.
16-39 Control Card Temp.
Range: Function:
0 C* [0 - 100 C] View the temperature on the control card,
stated in °C
16-40 Logging Buffer Full
Option: Function:
View whether the logging buffer is full (see parameter
group 15-1*). The logging buffer will never be full
when 15-13 Logging Mode is set to [0] Log always.
[0] * No
[1] Yes
16-48 Speed Ref. After Ramp [RPM]
Range: Function:
0 RPM* [-30000 - 30000
RPM]
This parameter specifies the
reference given to the drive after
the speed ramp.
16-49 Current Fault Source
Range: Function:
0 * [0 - 8 ] Value indicates source of current faults including
short circuit, over current, and phase imbalance
(from left):
1-4 Inverter
5-8 Rectifier
0 No fault recorded
3.17.3 16-5* Ref. & Feedb.
16-50 External Reference
Range: Function:
0.0 * [-200.0 -
200.0 ]
View the total reference, the sum of
digital, analog, preset, bus and freeze
references, plus catch-up and slow-down.
16-51 Pulse Reference
Range: Function:
0.0 * [-200.0 -
200.0 ]
View the reference value from
programmed digital input(s). The read-out
can also reflect the impulses from an
incremental encoder.
16-52 Feedback [Unit]
Range: Function:
0.000 Reference-
FeedbackUnit*
[-999999.999 -
999999.999
ReferenceFeed-
backUnit]
View the feedback unit
resulting from the
selection of unit and
scaling in 3-00 Reference
Range, 3-01 Reference/
Feedback Unit,
3-02 Minimum Reference
and 3-03 Maximum
Reference.
16-53 Digi Pot Reference
Range: Function:
0.00 * [-200.00 - 200.00 ] View the contribution of the Digital
Potentiometer to the actual
reference.
16-57 Feedback [RPM]
Range: Function:
0 RPM* [-30000 -
30000 RPM]
Read-out parameter where the actual
motor RPM from the feed-back source
can be read in both closed loop and
open loop. The feed-back source is
selected by 7-00 Speed PID Feedback
Source.
Parameter Descriptions
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark 145
3
3