2.1.11 Changing a Text Value
If the selected parameter is a text value, change the text
value with the [
] [
] keys.
Place the cursor on the value to save and press [OK].
130BP068.10
740RPM
0 -01 Language
[0] English
10.64 A 1 [1]
0-0
*
Basic Settings
Illustration 2.16
2.1.12 Changing a Group of Numeric Data
Values
If the chosen parameter represents a numeric data value,
change the chosen data value by means of the [
] [
]
navigation keys as well as the [
] [
] navigation keys. Press
[
] [
] keys to move the cursor horizontally.
130BP069.10
1- 6*
113 RPM 1.78 A 1(1)
Load depen. setting
1 - 60 Low speed load
compensation
100%
Illustration 2.17
Press [
] [
] keys to change the data value. [
] increases
the data value, and [
] decreases the data value. Place the
cursor on the value to save and press [OK].
130BP070.10
1 - 60 Low speed load
compensation
1 0%
Load depen. setting 1- 6*
729RPM 6.21A 1(1)
6
Illustration 2.18
2.1.13 Infinitely Variable Change of
Numeric Data Value
If the chosen parameter represents a numeric data value,
select a digit with [
] [
].
130BP073.10
635 RPM
1 - 71 Start Delay
00.0s
0.44 A 1 (1)
1- 7*
Start Adjustments
Illustration 2.19
Change the selected digit infinitely variably with [
] [
].
The chosen digit is indicated by the cursor. Place the
cursor on the digit to save and press [OK].
130BP072.10
957RPM
1-71 High starting torque time
0. s
11.58A 1 (1)
1-7*Start Adjustments
4
Illustration 2.20
2.1.14 Value, Step-by-Step
Certain parameters can be changed step by step or
infinitely varying. This applies to 1-20 Motor Power [kW],
1-22 Motor Voltage and 1-23 Motor Frequency.
The parameters are changed both as a group of numeric
data values and as numeric data values infinitely varying.
2.1.15
Read-out and Programming of
Indexed Parameters
Parameters are indexed when placed in a rolling stack.
15-30 Fault Log: Error Code to 15-32 Alarm Log: Time contain
a fault log which can be read out. Choose a parameter,
press [OK], and use [
] [
] to scroll through the value log.
Use 3-10 Preset Reference as another example:
Choose the parameter, press [OK], and use [
] [
] to scroll
through the indexed values. To change the parameter
value, select the indexed value and press [OK]. Change the
value by pressing [
] [
]. Press [OK] to accept the new
setting. Press [Cancel] to abort. Press [Back] to leave the
parameter.
The following instructions are valid for the Numerical LCP
(LCP 101).
The control panel is divided into four functional groups:
1. Numerical display.
2. Menu keys and indicator lights - changing
parameters and switching between display
functions.
How to Programme
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark 19