30-81 Brake Resistor (ohm)
Range: Function:
active in drives with an integral
dynamic brake.
30-83 Speed PID Proportional Gain
Range: Function:
Size related* [0.0000 -
1.0000 ]
Enter the speed controller propor-
tional gain. Quick control is
obtained at high amplification.
However if amplification is too
great, the process may become
unstable.
30-84 Process PID Proportional Gain
Range: Function:
0.100 * [0.000 -
10.000 ]
Enter the process controller propor-
tional gain. Quick control is obtained
at high amplification. However if
amplification is too great, the process
may become unstable.
Parameter Descriptions
VLT
®
AutomationDrive Programmming Guide
MG33ME02 - VLT
®
is a registered Danfoss trademark 155
3