5-33 Term X30/7 Digi Out (MCB 101)
Option: Function:
[126] Drive in auto mode
[151] ATEX ETR cur. alarm
[152] ATEX ETR freq. alarm
[153] ATEX ETR cur. warning
[154] ATEX ETR freq. warning
[189] External Fan Control
[190] Safe Function active
[191] Safe Opt. Reset req.
[192] RS Flipflop 0
[193] RS Flipflop 1
[194] RS Flipflop 2
[195] RS Flipflop 3
[196] RS Flipflop 4
[197] RS Flipflop 5
[198] RS Flipflop 6
[199] RS Flipflop 7
3.7.4 5-4* Relays
Parameters for configuring the timing and the output
functions for the relays.
5-40 Function Relay
Array [9]
(Relay 1 [0], Relay 2 [1], Relay 3 [2] (MCB 113), Relay 4 [3] (MCB
113), Relay 5 [4] (MCB 113), Relay 6 [5] (MCB 113), Relay 7 [6]
(MCB 105), Relay 8 [7] (MCB 105), Relay 9 [8] (MCB 105))
Option: Function:
[0] * No operation All digital and relay outputs are
default set to “No Operation”.
[1] Control ready The control card is ready. E.g.:
Feedback from a drive where the
control is supplied by an external 24
V (MCB 107) and the main power to
drive is not detected.
[2] Drive ready Drive is ready to operate. Mains and
control supplies are OK.
[3] Drive rdy/rem ctrl The frequency converter is ready for
operation and is in Auto On mode
[4] Enable / no warning Ready for operation. No start or stop
commands have been applied (start/
disable). No warnings are active.
[5] Running Motor is running, and shaft torque
present.
[6] Running / no
warning
Output speed is higher than the
speed set in 1-81 Min Speed for
Function at Stop [RPM] Min Speed for
Function at Stop [RPM]. The motor is
running and no warnings.
[7] Run in range/no
warn
Motor is running within the
programmed current and speed
5-40 Function Relay
Array [9]
(Relay 1 [0], Relay 2 [1], Relay 3 [2] (MCB 113), Relay 4 [3] (MCB
113), Relay 5 [4] (MCB 113), Relay 6 [5] (MCB 113), Relay 7 [6]
(MCB 105), Relay 8 [7] (MCB 105), Relay 9 [8] (MCB 105))
Option: Function:
ranges set in 4-50 Warning Current
Low and 4-53 Warning Speed High.
No warnings.
[8] Run on ref/no warn Motor runs at reference speed. No
warnings.
[9] Alarm An alarm activates the output. No
warnings
[10] Alarm or warning An alarm or a warning activates the
output.
[11] At torque limit
The torque limit set in 4-16 Torque
Limit Motor Mode or 4-17 Torque
Limit Generator Mode has been
exceeded.
[12] Out of current
range
The motor current is outside the
range set in 4-18 Current Limit.
[13] Below current, low
Motor current is lower than set in
4-50 Warning Current Low.
[14] Above current, high
Motor current is higher than set in
4-51 Warning Current High.
[15] Out of speed range Output speed/frequency is outside
the frequency range set in
4-52 Warning Speed Low and
4-53 Warning Speed High.
[16] Below speed, low Output speed is lower than the
setting in 4-52 Warning Speed Low
[17] Above speed, high Output speed is higher than the
setting in 4-53 Warning Speed High.
[18] Out of feedb. range
Feedback is outside the range set in
4-56 Warning Feedback Low and
4-57 Warning Feedback High.
[19] Below feedback, low
Feedback is below the limit set in
4-56 Warning Feedback Low.
[20] Above feedback,
high
Feedback is above the limit set in
4-57 Warning Feedback High.
[21] Thermal warning Thermal warning turns on when the
temperature exceeds the limit either
in motor, frequency converter, brake
resistor, or connected thermistor.
[22] Ready,no thermal W Frequency converter is ready for
operation and there is no over-
temperature warning.
[23] Remote,ready,no TW Frequency converter is ready for
operation and is in Auto On mode.
Parameter Descriptions