FC 300 Design Guide
How to Program
Idle Time [9913]
Paramdb Requests in Queue [9914]
Function:
None [0] No disp lay value chosen
Control Word [1600] Displays the
present control w ord
Reference [Unit] [1601] displays the status valu
e
of terminals 53 or 54 using the unit stated on the
basis of configuration in P.1-00 (RPM or Nm).
Reference % [1602] displays the total
reference (sum of digital/analog/preset/b us/freeze
ref./catch up and slow-d own).
Status Word [binary] [1603] Displays
the present status word
Alarm Word [1604] indicates one or several
alarms in a Hex code.
Warning Word [1605] indicates one or
more warnings in a Hex code.
Extended Status Word [1606] [He
x] indicates
one or more status states in a Hex code.
Power [kW] [1610] sta tes the actual power
consumed by the m otor in kW
.
Power [hp] [1611] states the actual power
consumed by the motor in HP.
Motor voltage [V] [1612] st
ates the voltage
supplied to the motor.
Frequency [Hz] [1613] gives the motor
frequency, i.e. the ou
tput frequency from the
adjustable frequency drive.
Motor Current [A] [1614] states the pha se
current of the motor m
easured as effective value.
Torque [%] [1616] gives the current motor load
in rel ation to the rated motor torque.
Speed [RPM] [1617] D
isplays the speed in
RPM (revolutions per Minute) i.e. the m otor
shaft speed in closed-loop.
Motor Thermal [161
8] states the calculated/es-
timated thermal load on the motor.
DC Link Voltage [V] [ 16 3 0] states the
intermediate ci
rcuit voltage in the adjustable
frequency drive.
Brake Energy /s [1632] states the present brake
power transfer
red to an external brake resistor.
Stated as an instantaneous value.
Brake Energy /2 min [1633] states the brake
power transf
erred to an external brake resistor.
The mean powe r is calculated continuously
for the latest 120 seconds.
Heatsink Temp. [°C] [1634] states the present
heatsink temperature of the adjustable frequency
drive. The cut-out limit is 203 ± 9°F (95 ± 5°C);
resetoccursat158±9°F(70±5°C).
Inverter Thermal [1635] returns the
percentage load of the inverters.
Inv. Nom. Current [1636] The nominal current
of the adjustable frequency drive.
Inv. Max. Current [1637] The maximum current
of the adjustable frequency drive.
SL Controller State [1638] returns the state
of the event executed by the control.
Control Card Temp. [1639] re turns the
temperature on control card.
External Reference [1650] [%] gives the
sum of the external reference as a percentage
(the sum of analog/pulse /bus).
Pulse Reference [1651] [Hz] states the
frequency in H z connected to the programmed
digital inputs (18, 19 or 32, 33).
Feedback [Unit] [1652] returns the re ference
value from programmed digital input(s).
Digital Input [1660] states the signal states
from the 6 digital ter minals (18, 19, 27, 29, 32
and 33) Input 18 corresponds to the bit at the far
left. "0" = signal low; " 1" = signal high.
Terminal 53 Switch Setting [1661]
returns the setting of input terminal 5 3.
Current=0;Voltage=1.
Analog Input 53 [1662] returns the actual value
on input 53 either as reference or protection value.
Terminal 54 Switch Setting [1663]
returns the setting of input terminal 5 4.
Current=0;Voltage=1.
Analog Input 54 [1664] returns the actual value
on input 54 either as reference or protection value.
Analog Output 42 [mA] [1665] re turns the
actual value in mA on o utp u t 42. Selection of
shown value is set in par. 6-50.
Digital Output [bin] [1666] returns the bin
value of all digital outputs.
Freq. Input #29 [Hz] [1667] returns
the actual value of the frequency applied on
terminal 29 as an impulse input.
Freq. Input #33 [Hz] [1668] returns
the actual value of the frequency applied on
terminal 33 as an impulse input.
Pulse output #27 [Hz] [1669] returns the
actual value of impulses applied to ter
minal
27 in digital output mode.
*
default setting ()display text []value for use in communication via serial communication port
135
MG.33.B
3.22 - VLT is a registered Danfoss trademark