FC 300 Design Guide
How to Program
Power [hp] [1611] states the actual power
consumed by the motor in HP.
Motor Voltage [V] [1612] states the voltage
supplied to the motor.
Frequency [Hz] [1613] gives the motor
frequency, i.e. the output frequency from the
adjustable frequency drive.
Motor Current [A] [1614] states the pha se
current of the motor measured as effective value.
Torque [%] [1616] gives the current motor load
in rel ation to the rated motor torque.
Speed [RPM] [1617] Display the speed
in RPM (revolutions per minute) i.e. the
crankshaft speed in closed loop.
Motor thermal [1618] stat es the calculated/es-
timated thermal load on the motor.
DC Link Voltage [V] [ 16 3 0] states the
intermediate circuit voltage in the adjustable
frequency drive.
BrakeEnergy/s [1632] st ates the present brake
power transferred to an external brake resistor.
Stated as an instantaneous value.
BrakeEnergy/2 min [1633] states the brake
power transferred to an external brake resistor.
The mean powe r is calculated continuously
for the latest 120 seconds.
Heatsink Tem perature [°C] [1634] states
the present hea t sink temperature of the
adjustable frequency drive. The cut-out lim it
is203±9°F(95±5°C);cuttingbackin
occursat158±9°F(70±5°C).
Inverter thermal [1635] returns the percentage
load of the inverters.
InomVLT [1636] The nominal current of the
adjustable frequency drive.
ImaxVLT [1637] The m aximum current of
the adjusta ble frequency drive.
Condition controller state [1638] re turns the
state of the event e xecuted by the controller.
Data read-out: Control Card Temperature
[1639] returns the te mpe rature on control card.
External Reference [1650] [%] gives the
sum of the external re ference as a percentage
(the sum of analog/pulse/bus).
Pulse Reference [1651] [Hz] states the
frequency in Hz connected to the programmed
digital inputs (18, 19 or 32, 33).
Feedba ck [U nit] [1652] returns the reference
value from programmed digital input(s
).
Digital Input [1660] states the signal states
from the 6 digital ter minals (18, 19, 27, 29, 32
and 33) Input 18 corresponds to the bit at the far
left. "0" = signal low; " 1" = signal high.
Terminal 53 Switch Setting [1661]
returns the setting of input terminal 5 3.
Current=0;Voltage=1.
Analog Input 53 [1662] returns the actual value
on input 53 either as reference or protection value.
Terminal 54 Switch Setting [1663]
returns the setting of input terminal 5 4.
Current=0;Voltage=1.
Analog Input 54 [1664] returns the actual value
on input 54 either as reference or protection value.
Analog Output 42 [mA] [1665] re turns the
actual value in mA on o utp u t 42. Selection of
shown value is set in par. 06-50.
Digital Output [bin] [1666] returns the bin
value of all digital outputs.
Frequency input #29 [Hz] [1667] returns
the actual value of the frequency applied on
terminal 29 as an impulse input.
Frequency input #33 [Hz] [1668] returns
the actual value of the frequency applied on
terminal 33 as an impulse input.
Pulse output #27 [Hz] [1669] returns the
actual value of impulses applied to terminal
27 in digital output mode.
Pulse output #29 [Hz] [1670] returns the
actual value of impulses applied to terminal
29 in digital output mode.
Fieldbus control word1 signal [ 1680] Control
word (CTW) received from the Bus Master.
Fieldbus status word1 signal [1681] Status
word (STW) sent to the Bus Master.
Fieldbus speed setpoint A signal [1682]
Main reference value sent with control word
form the Bus Master.
Fieldbus speed actual value A signal
[1683] Ma in actual value sen d w ith the Status
word to the Bus Master.
Communication Option Status Word
[binary] [1684] Extended fieldbus comm.
option status word.
FC port control word1 signal [1685] Control
word (CTW) received from the Bus Master.
FC port speed setpoint A signal [1686] Status
word (STW) sent to the Bus Master.
*
default setting ()display text []value for use in communication via serial communication port
137
MG.33.B
3.22 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals