6.12 Parameters: 15-** Drive Information
6.12.1 15-** Drive Information
Parameter group containing compressor drive information
such as operating data, hardware configuration and
software versions.
6.12.2 15-0* Operating data
Parameter group containing operating data, e.g. counters.
15-00 Operating Hours
Range: Function:
0 h* [0 - 2147483647 h] View how many hours the frequency
converter has run. The value is saved
when the frequency converter is
turned off.
15-01 Running Hours
Range: Function:
0 h* [0 - 2147483647
h]
View how many hours the motor has
run. Reset the counter in 15-07 Reset
Running Hours Counter. The value is
saved when the frequency converter is
turned off.
15-02 kWh Counter
Range: Function:
0 kWh* [0 - 2147483647
kWh]
Registering the power consumption
of the motor as a mean value over
one hour. Reset the counter in
15-06 Reset kWh Counter.
15-03 Power Up's
Range: Function:
0 * [0 - 2147483647 ] View the number of times the frequency
converter has been powered up.
15-04 Over Temp's
Range: Function:
0 * [0 - 65535 ] View the number of frequency converter
temperature faults which have occurred.
15-05 Over Volt's
Range: Function:
0 * [0 - 65535 ] View the number of frequency converter
overvoltages which have occurred.
15-06 Reset kWh Counter
Option: Function:
[0] * Do not reset Nno reset of the kWh counter is desired.
[1] Reset counter Press [OK] to reset the kWh counter to zero
(see 15-02 kWh Counter).
NOTE
The reset is carried out by pressing [OK].
15-07 Reset Running Hours Counter
Option: Function:
[0] * Do not reset
[1] Reset counter
Select [1] Reset and press [OK] to reset the
Running Hours counter to zero (see
15-01 Running Hours). This parameter cannot
be selected via the serial port, RS-485.
Select [0] Do not reset if no reset of the
Running Hours counter is desired.
15-08 Number of Starts
Range: Function:
[0 - 4294967295] View the total number of starts performed
since power-on. The value is cleared to zero
at power-up.
15-09 Number of Auto Resets
Range: Function:
[0 - 4294967295] View the total number of auto resets
performed since power-on. The counter is
cleared to zero at power-up.