EasyManua.ls Logo

Danfoss VLT Midi Drive FC 280

Danfoss VLT Midi Drive FC 280
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-7* Start Adjustments
1-70 PM Start Mode [0] Rotor Detection All set-ups TRUE - Uint8
1-71 Start Delay 0 s All set-ups TRUE -1 Uint8
1-72 Start Function [2] Coast/delay time All set-ups TRUE - Uint8
1-73 Flying Start [0] Disabled All set-ups TRUE - Uint8
1-75 Start Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-76 Start Current ExpressionLimit All set-ups TRUE -2 Uint32
1-78 Compressor Start Max Speed [Hz] 0 Hz All set-ups TRUE -1 Uint16
1-79 Compressor Start Max Time to Trip 5 s All set-ups TRUE -1 Uint8
1-8* Stop Adjustments
1-80 Function at Stop [0] Coast All set-ups TRUE - Uint8
1-82 Min Speed for Function at Stop [Hz] 0 Hz All set-ups TRUE -1 Uint16
1-83 Precise Stop Function
[0] Precise ramp
stop All set-ups FALSE - Uint8
1-84 Precise Stop Counter Value 100000 N/A All set-ups TRUE 0 Uint32
1-85
Precise Stop Speed Compensation
Delay 10 ms All set-ups TRUE -3 Uint8
1-88 AC Brake Gain 1.4 N/A All set-ups TRUE -1 Uint16
1-9* Motor Temperature
1-90 Motor Thermal Protection [0] No protection All set-ups TRUE - Uint8
1-93 Thermistor Source [0] None All set-ups FALSE - Uint8
5.2.3 2-** Brakes
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
2-0* DC-Brake
2-00 DC Hold/Motor Preheat Current 50 % All set-ups TRUE 0 Uint16
2-01 DC Brake Current 50 % All set-ups TRUE 0 Uint16
2-02 DC Braking Time 10 s All set-ups TRUE -1 Uint16
2-04 DC Brake Cut In Speed 0 Hz All set-ups TRUE -1 Uint16
2-06 Parking Current 100 % All set-ups TRUE 0 Uint16
2-07 Parking Time 3 s All set-ups TRUE -1 Uint16
2-1* Brake Energy Funct.
2-10 Brake Function [0] O All set-ups TRUE - Uint8
2-11 Brake Resistor (ohm) ExpressionLimit All set-ups FALSE -1 Uint16
2-12 Brake Power Limit (kW) ExpressionLimit All set-ups TRUE 0 Uint32
2-14 Brake voltage reduce 0 V All set-ups FALSE 0 uint16
2-16 AC Brake, Max current 100 % All set-ups TRUE -1 Uint16
2-17 Over-voltage Control [0] Disabled All set-ups TRUE - Uint8
2-19 Over-voltage Gain 100 % All set-ups TRUE 0 Uint16
2-2* Mechanical Brake
2-20 Release Brake Current 0 A All set-ups TRUE -2 Uint32
2-22 Activate Brake Speed [Hz] 0 Hz All set-ups TRUE -1 Uint16
2-23 Activate Brake Delay 0 s All set-ups TRUE -1 Uint8
Parameter Lists
VLT
®
Midi Drive FC 280
118 Danfoss A/S © 12/2015 All rights reserved. MG07C102
55

Other manuals for Danfoss VLT Midi Drive FC 280

Related product manuals