Function Set-ups parameters
The Function Set-ups parameters are grouped in the following way:
Q3-1 General Settings
Q3-10 Adv. Motor Settings Q3-11 Analog Output Q3-12 Clock Settings Q3-13 Display Settings
par.1-90
Motor Thermal Protection
par.6-50
Terminal 42 Output
par.0-70
Set Date and Time
par.0-20
Display Line 1.1 Small
par.1-93
Thermistor Source
par.6-51
Terminal 42 Output Min
Scale
par.0-71
Date Format
par.0-21
Display Line 1.2 Small
par.1-29
Automatic Motor Adapta-
tion (AMA)
par.6-52
Terminal 42 Output Max
Scale
par.0-72
Time Format
par. 0-22
Display Line 1.3 Small
par.14-01
Switching Frequency
par.0-74
DST/Summertime
par. 0-23
Display Line 2 Large
par.4-53
Warning Speed High
par.0-76
DST/Summertime Start
par. 0-24
Display Line 3 Large
par.0-77
DST/Summertime End
par.0-37
Display Text 1
par.0-38
Display Text 2
par.0-39
Display Text 3
Q3-2 Open-loop Settings
Q3-20 Digital Reference Q3-21 Analog Reference
par.3-02
Minimum Reference
par.3-02
Minimum Reference
par.3-03
Maximum Reference
par.3-03
Maximum Reference
par.3-10
Preset Reference
par.6-10
Terminal 53 Low Voltage
par. 5-13
Terminal 29 Digital Input
par.6-11
Terminal 53 High Voltage
par.5-14
Terminal 32 Digital Input
par. 6-12
Terminal 53 Low Current
par. 5-15
Terminal 33 Digital Input
par. 6-13
Terminal 53 High Current
par.6-14
Terminal 53 Low Ref./Feedb. Value
par.6-15
Terminal 53 High Ref./Feedb. Value
Q3-3 Closed-loop Settings
Q3-30 Single Zone Int. Setpoint Q3-31 Single Zone Ext. Setpoint Q3-32 Multi Zone / Adv
par.1-00
Configuration Mode
par.1-00
Configuration Mode
par.1-00
Configuration Mode
par. 20-12
Reference/Feedback Unit
par. 20-12
Reference/Feedback Unit
par.3-15
Reference 1 Source
par. 20-13
Minimum Reference/Feedb.
par. 20-13
Minimum Reference/Feedb.
par.3-16
Reference 2 Source
par. 20-14
Maximum Reference/Feedb.
par. 20-14
Maximum Reference/Feedb.
par.20-00
Feedback 1 Source
par. 6-22
Terminal 54 Low Current
par.6-10
Terminal 53 Low Voltage
par.20-01
Feedback 1 Conversion
par.6-24
Terminal 54 Low Ref./Feedb. Value
par.6-11
Terminal 53 High Voltage
par. 20-02
Feedback 1 Source Unit
par.6-25
Terminal 54 High Ref./Feedb. Value
par. 6-12
Terminal 53 Low Current
par.20-03
Feedback 2 Source
par.6-26
Terminal 54 Filter Time Constant
par. 6-13
Terminal 53 High Current
par.20-04
Feedback 2 Conversion
par.6-27
Terminal 54 Live Zero
par.6-14
Terminal 53 Low Ref./Feedb. Value
par. 20-05
Feedback 2 Source Unit
par.6-00
Live Zero Timeout Time
par.6-15
Terminal 53 High Ref./Feedb. Value
par.20-06
Feedback 3 Source
par.6-01
Live Zero Timeout Function
par. 6-22
Terminal 54 Low Current
par.20-07
Feedback 3 Conversion
par.20-21
Setpoint 1
par.6-24
Terminal 54 Low Ref./Feedb. Value
par. 20-08
Feedback 3 Source Unit
par.20-81
PID Normal/ Inverse Control
par.6-25
Terminal 54 High Ref./Feedb. Value
par. 20-12
Reference/Feedback Unit
par. 20-82
PID Start Speed [RPM]
par.6-26
Terminal 54 Filter Time Constant
par. 20-13
Minimum Reference/Feedb.
par. 20-83
PID Start Speed [Hz]
par.6-27
Terminal 54 Live Zero
par. 20-14
Maximum Reference/Feedb.
par.20-93
PID Proportional Gain
par.6-00
Live Zero Timeout Time
par.6-10
Terminal 53 Low Voltage
par.20-94
PID Integral Time
par.6-01
Live Zero Timeout Function
par.6-11
Terminal 53 High Voltage
par. 20-70
Closed-loop Type
par.20-81
PID Normal/ Inverse Control
par. 6-12
Terminal 53 Low Current
par. 20-71
Tuning Mode
par. 20-82
PID Start Speed [RPM]
par. 6-13
Terminal 53 High Current
par. 20-72
PID Output Change
par. 20-83
PID Start Speed [Hz]
par.6-14
Terminal 53 Low Ref./Feedb. Value
par. 20-73
Minimum Feedback Level
par.20-93
PID Proportional Gain
par.6-15
Terminal 53 High Ref./Feedb. Value
par. 20-74
Maximum Feedback Level
par.20-94
PID Integral Time
par.6-16
Terminal 53 Filter Time Constant
par. 20-79
PID Auto Tuning
par. 20-70
Closed-loop Type
par.6-17
Terminal 53 Live Zero
par. 20-71
Tuning Mode
par.6-20
Terminal 54 Low Voltage
par. 20-72
PID Output Change
par.6-21
Terminal 54 High Voltage
par. 20-73
Minimum Feedback Level
par. 6-22
Terminal 54 Low Current
par. 20-74
Maximum Feedback Level
par. 6-23
Terminal 54 High Current
par. 20-79
PID Auto Tuning
par.6-24
Terminal 54 Low Ref./Feedb. Value
par.6-25
Terminal 54 High Ref./Feedb. Value
par.6-26
Terminal 54 Filter Time Constant
par.6-27
Terminal 54 Live Zero
par.6-00
Live Zero Timeout Time
par.6-01
Live Zero Timeout Function
par.4-56
Warning Feedback Low
par.4-57
Warning Feedback High
par.20-20
Feedback Function
par.20-21
Setpoint 1
par.20-22
Setpoint 2
par.20-81
PID Normal/ Inverse Control
par. 20-82
PID Start Speed [RPM]
par. 20-83
PID Start Speed [Hz]
par.20-93
PID Proportional Gain
par.20-94
PID Integral Time
6 How to program the adjustable frequency
drive
VLT
®
HVAC Drive Instruction Manual
6-12
MG.11.A9.22 - VLT
®
is a registered Danfoss trademark
6