EasyManua.ls Logo

Danfoss VLT - User Manual

Danfoss VLT
179 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Contents
1 Safety
1-1
Safety instructions 1-1
Before Commencing Repair Work 1-2
Special conditions 1-2
Avoid unintended Start. 1-3
Safe Stop of the Adjustable Frequency Drive 1-3
IT Line Power 1-5
2 Introduction
2-1
3 Mechanical installation
3-1
Before starting 3-1
Mechanical Dimensions 3-3
4 Electrical installation
4-1
How to connect 4-1
Line power wiring overview 4-6
Motor wiring overview 4-13
DC bus connection 4-17
Brake Connection Option 4-18
Relay Connection 4-20
How to Test Motor and Direction of Rotation. 4-24
Electrical Installation and Control Cables 4-27
5 How to operate the adjustable frequency drive
5-1
Three ways of operating 5-1
How to operate the numeric LCP (NLCP) 5-1
Tips and tricks 5-5
6 How to program the adjustable frequency drive
6-1
How to program 6-1
Quick Menu Mode 6-1
Function Set-ups 6-10
Parameter list 6-55
Main Menu Structure 6-55
0-** Operation and Display 6-56
1-** Load / Motor 6-58
2-** Brakes 6-59
VLT
®
HVAC Drive Instruction Manual Contents
MG.11.A9.22 - VLT
®
is a registered Danfoss trademark

Other manuals for Danfoss VLT

Questions and Answers

  • C
    caseycherryAug 27, 2025
    What causes DC under voltage in Danfoss VLT DC Drives and how to fix it?
    • B
      Brendan MorganAug 27, 2025
      If the intermediate circuit voltage (DC) drops below the under voltage limit, check that the supply voltage matches the frequency converter voltage.
  • D
    Daniel PerryAug 27, 2025
    What to do if Danfoss VLT DC Drives report heatsink temp issue?
    • H
      Holly NguyenAug 27, 2025
      If the maximum temperature of the heatsink has been exceeded, check for high ambient temperature or blocked airflow.
  • D
    Dr. Andrew Chapman IIAug 28, 2025
    What to do if Danfoss VLT display control word timeout?
    • B
      blakenunezAug 28, 2025
      If there is no communication to the frequency converter, check connections on the serial communication cable.
  • C
    Chelsea LeonardAug 28, 2025
    What to do if Danfoss DC Drives report motor phase U missing?
    • M
      Michael OdomAug 29, 2025
      If motor phase U between the frequency converter and the motor is missing, remove power from the frequency converter and check motor phase U.
  • M
    Matthew WoodsAug 29, 2025
    What to do if Danfoss VLT DC Drives report motor phase V missing?
    • S
      Scott CaldwellAug 29, 2025
      If motor phase V between the frequency converter and the motor is missing, remove power from the frequency converter and check motor phase V.
  • D
    Dr. Christopher CraneAug 30, 2025
    What to do if Danfoss DC Drives report motor phase W missing?
    • K
      Kenneth RochaAug 30, 2025
      If motor phase W between the frequency converter and the motor is missing, remove power from the frequency converter and check motor phase W.
  • S
    Sandra MullenAug 30, 2025
    How to troubleshoot 10 Volts low on Danfoss DC Drives?
    • T
      Tim HerringAug 30, 2025
      If the control card voltage is below 10 V from terminal 50, remove some of the load from terminal 50, as the 10 V supply is overloaded.
  • N
    nicole09Aug 31, 2025
    What to do if Danfoss VLT DC Drives indicate an internal fault?
    • S
      scottaprilAug 31, 2025
      If an internal fault occurs, indicated by a code number, cycle power to the frequency converter.
  • J
    Jamie StoneAug 25, 2025
    What to do if Danfoss VLT show mains failure?
    • Z
      Zachary EllisAug 25, 2025
      If the supply voltage to the frequency converter is lost, check the fuses to the frequency converter and the mains power supply.
  • W
    Wayne PerrySep 1, 2025
    Why Danfoss DC Drives show torque limit?
    • A
      Ashley LeachSep 1, 2025
      If the torque has exceeded the value in 4-16 Torque Limit Motor Mode or the value in 4-17 Torque Limit Generator Mode, and the motor torque limit is exceeded during ramp up, extend the ramp up time.

Summary

1 Safety

1.1.2 High Voltage Warning

Warning about dangers of high voltage during operation and installation.

1.1.3 Safety Instructions

General safety instructions for operating the adjustable frequency drive.

1.1.4 Before Commencing Repair Work

Procedures to follow before starting any repair or maintenance work.

1.1.8 Avoid Unintended Start

Precautions to prevent accidental motor startup during operation or setup.

1.1.9 Safe Stop of the Adjustable Frequency Drive

Information on the Safe Stop function and its compliance with safety categories.

3 Mechanical Installation

3.2.5 Safety Requirements for Mechanical Installation

Crucial safety precautions for mechanical installation procedures.

4 Electrical Installation

4.1 How to Connect

Instructions for connecting the electrical components of the drive.

4.1.2 Fuses

Information on selecting and using fuses for circuit protection.

4.1.23 How to Test Motor and Direction of Rotation

Procedure to test motor connection and verify rotation direction.

5 How to Operate the Adjustable Frequency Drive

6 How to Program the Adjustable Frequency Drive

6.1 How to Program

Steps and methods for programming the drive's various functions.

7 Troubleshooting

7.1 Alarms and Warnings

How alarms and warnings are signaled, their causes, and reset procedures.

7.1.2 Fault Messages

Detailed list of fault messages, their meanings, and corrective actions.

Danfoss VLT Specifications

General IconGeneral
Frequency50/60 Hz
EnclosureIP20, IP21, IP55, IP66
SeriesVLT
Control TechniqueFlux Vector Control
Output Voltage0-Vinput
Control MethodFieldbus
Communication InterfacePROFIBUS, CANopen
Protection FeaturesOverload, Overvoltage, Undervoltage, Short Circuit, Ground Fault
Cooling MethodLiquid Cooled
Storage Temperature-25°C to +70°C
Relative Humidity5-95% non-condensing
AltitudeUp to 1000m (3280ft) without derating, up to 4000m (13120ft) with derating
Operating Temperature-10°C to +50°C (14°F to 122°F)