ENTER/EXIT PROGRAMMING MODE SYMBOLOGIES
168
   GRYPHON™ I GD/GBT/GM4200
Codabar Length Control
This feature specifies either variable length decoding or fixed length decoding for the 
Codabar symbology.
Variable Length: For variable-length decoding, a minimum length may be set.
Fixed Length: For fixed-length decoding, two different lengths may be set.
Codabar Set Length 1
This feature specifies one of the bar code lengths for "Codabar Length Control" on page 
168. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed 
length if in Fixed Length Mode. Length includes the bar code’s start, stop, check and 
data characters. The length must include at least one data character.
The length can be set from 3 to 50 characters. See "Set Length 1" on page 247 for more 
detailed programming instructions.
$CCBLC00
Codabar Length Control = Variable Length
Codabar Length Control = Fixed Length
$CCBLC01
Select Codabar Length 1 Setting
$CCBL1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the 
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
Length 1 = 03 (3 characters)