REFERENCES
242
   GRYPHON™ I GD/GBT/GM4200
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode. The select-
able range is 100 to 9,900 milliseconds (0.1 
to 9.9 seconds), in 100 millisecond incre-
ments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result 
with 
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming 
Mo
de.
4. Scan the bar code: SELECT FLASH ON TIME SETTING on 
page 93.
5. Scan the appropriate two digits from the keypad in 
Appendix D, that represent the 
duration which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this fea-
ture.
Table 19 Flash On Time Setting Examples
NOTE: If you make a mistake before the last character, scan the CANCEL 
bar code to abort and not save the entry string. You can then start again at 
the beginning.
STEP
ACTION EXAMPLES
1 Desired Setting
500ms
1,000ms
(1 sec.)
5200ms
(5.2 sec.)
9,900ms
(9
.9 sec.)
2
Divide by 100
 
(and pad with leading zeroes to 
yield two digits)
05 10 52 99
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT FLASH ON TIME SETTING
5
Scan two characters from 
Appendix D
‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’
6 Scan ENTER/EXIT PROGRAMMING MODE