LED AND BEEPER INDICATORS ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
107
Silent Mode
If needed, audible indications can be disabled by scanning the labels below.
Please note that some important audible notifications are not muted in silent mode and
other notifications are replaced by vibration or visual indications.
All changes in audible notifications are summarized here:
Good Read beep is replaced with vibration
Power on beep is replaced with vibration
Connection / Disconnection / out of radio range beeps are replaced with blue LED
and vibration
Error beep, RF Error/timeout beeps, chirp beeps are replaced with red 3GL and
vibration
Battery beeps, programming labels, and RF paging beeps are not muted
RGB Good Read Enable
Specifies whether the RGB good read indicator is enabled or disabled.
SilentModeON
Silent Mode = Enable
Silent Mode = Disable
SilentModeOFF
$CRBGE00
RGB Good Read = Disable
RGB Good Read = Enable
$CRBGE01