ENTER/EXIT PROGRAMMING MODE 1D SYMBOLOGIES
148
GRYPHON™ I GD/GBT/GM4500
CODE 128
The following options apply to the Code 128 symbology.
Code 128 Enable/Disable
Enables/Disables ability of the reader to decode Code 128 labels.
Expand Code 128 to Code 39
This feature enables/disables expansion of Code 128 labels to Code 39 labels. When
enabled, the label identifier for a Code 128 label shall be set to Code 39 and all Code 39
formatting control shall be applied to the label.
$CC8EN00
Code 128 = Disable
Code 128 = Enable
$CC8EN01
$CC8C300
Code 128 to Code 39 = Don’t Expand
Code 128 to Code 39 = Expand
$CC8C301