Programming
5-190 Magellan
TM
2200VS and 2300HS
RSS Expanded Minimum Label Length
This feature specifies the minimum allowable length of an RSS Expanded
label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET RSS EXPANDED MINIMUM LABEL
LENGTH
below. Youll need to cover any unused bar codes on this
and the facing page to ensure that the scanner reads only the bar
code you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired minimum label length. The selectable range for
this option is 00 to 74. Pad all single digit numbers with a leading
zero to yield a two-digit entry (00-74).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET RSS EXPANDED MINIMUM LABEL LENGTH
NOTE
Length in this case includes check and data characters. This
applies when RSS Expanded Length Control is set to vari-
able-length decoding.
Minimum Label Length should be less than or equal to Maxi-
mum Label Length.