EasyManua.ls Logo

Datalogic Magellan 2200VS

Datalogic Magellan 2200VS
388 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Reference Guide F-7
Code 39
Check character must be included in label data.
Label length including start, stop and check characters and exclud-
ing prefix character must meet requirements imposed by the main
scanner's fixed or variable label length control for this symbology
type.
Start and stop characters "*" must be included in label.
Prefix must be an ASCII character '*'.
Example : '**Code 39.TEST*'.
Code 39-Pharmacode
Check character must be included in label data.
Label length including start, stop and check characters and exclud-
ing prefix character must meet requirements imposed by the main
scanner's fixed or variable label length control for this symbology
type.
Start and stop characters "*" must be included in label.
Prefix must be an ASCII character 'p'.
Example: 'p*123456789*'.
I 2 of 5
Check character must be included in label data.
Label length including check characters and excluding prefix charac-
ter must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.
Prefix must be an ASCII character 'i'.
Example: 'i0123456789'.

Table of Contents

Other manuals for Datalogic Magellan 2200VS

Related product manuals